English
Language : 

CC-1448-12 Datasheet, PDF (1/1 Pages) JMK Inc. – single phase filter
Operating Voltage = 250 Vac or Vdc @75oC
Operating Voltage = 125 Vac or Vdc @100oC
Operating Current (Max) = 12 AMP A/C or D/C
Frequency = DC—60 HZ
Temp range (Storage) = -40 to 125oC
Temp range (Operating) @ 12.0 AMP= -65—100oC
Dielectric Withstand voltage (Ph—Case) = 1500 Vac
Dielectric Withstand voltage (Ph—Ph) = 1500 Vdc
Leakage current @ 250 V~, 60 HZ = 2.5 MA max.
Discharge Voltage after 60 sec = 34 V max.
Weight = 1300 gram / 2.9 lb.
Hermetically sealed
Order p/n: CC-1448-12
CC-1448-12
LINE
LOAD
90
80
CM
70
60
50
40
DM
30
20
10
0
.01 .04 .1
.4 1
4 10
40 100
.02 .07 .2
.7 2
7 20 70
FREQUENCY (MEGAHERTZ)
The CC-1448-12 is a
single phase filter de-
signed to function in the
Mil-Std-461D
Mil-Std-461E &
Mil-Std-461F emissions
Environment.
The filter is also de-
2.25
signed to function over a
wide temperature range
from –65 to +100 C.
2.40
The fiter is hermetically
sealed to meet moisture
and immersion require-
ments,
5.50
2.25
1.60
0.42
0.25
0.25
1.900
5.000
1.60
8-32 INSERT (4X)
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com
JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 FX: 44-(0) 141 588 1884