English
Language : 

CD29LQL Datasheet, PDF (1/4 Pages) Jianghai Europe GmbH – EC Snap-In 85°C Long Lifetime 7.000h Highest Ripple Currents Largest Size(Snap-In)
CD 29L QL Series
7 000h at 85°C
· Larger Size Components
· Long Useful Life
· High Ripple Current
· Industrial Power Supplies
CD 296 KC
CD 293 BZ
longer
life
105°C
CD 295 BC
larger size
higher current
highest
current
longest
life
CD 29D HR
CD 29L QL
Item
Operating Temperature Range (°C)
Voltage Range (V)
Capacitance Range (µF)
Capacitance Tolerance
(20°C, 120Hz)
Leakage Current (µA)
-40 ~ +85
16 ~ 400
Characteristics
390 ~ 120 000
± 20%
-25 ~ +85
450 ~ 500
After 5 minutes at 20°C application of rated voltage, leakage
current is not more than 0,01CV or 1,5mA, whichever is smaller 
C: Nominal Capacitance (µF) V: Rated Voltage (V)
Dissipation Factor (20°C, 120Hz)
Rated Voltage (V)
Tan δ (max)
16 25 35 50 63 ~ 100 160 ~ 250 350 ~ 450
0,60 0,50 0,40 0,30 0,20
0,15
500
Stability at Low Temperature
(Impedance Ratio at 120Hz)
Rated Voltage (V)
Z -25°C / Z +20°C
Z -40°C / Z +20°C
16 ~35
4
15
50 ~ 100 160 ~ 200 250 ~ 400
3
10
6
8
450
500
4
-
Lifetime
Leakage Current
Capacity Change
Dissipation Factor
Condition:
Applied Voltage
Applied Current
Applied Temperature
Failure Rate Level
Useful Life
Load Life
Endurance Test
Shelf Life
7 000h
>100 000h
5 000h
5 000h
1 000h
Not more than specified value
Within ± 30% of initial value
Not more than 300% of specified value
Not more than specified Not more than specified
value
value
Within ± 20% of initial
value
Within ± 20% of initial
value
Not more than 200% of Not more than 130% of
specified value
specified value
Not more than specified
value
Within ± 20% of initial
value
Not more than 200% of
specified value
UR
IR
85°C
≤ 1% Failure Rate
UR
1,2 x IR
40°C
UR
IR
85°C
≤ 1% Failure Rate guaranteed
UR
IR = 0
85°C
UR = 0
IR = 0
85°C
After test:
UR to be applied
for 30min
>24h before
measurement
Multiplier for Ripple Current
Frequency Coefficient
Rated
Voltage (V)
Frequency
50Hz 120Hz 1kHz 10kHz 100kHz
≤ 50
63 ~ 100
≥ 160
0,95 1,00 1,10 1,15 1,15
0,90 1,00 1,16 1,30 1,33
0,85 1,00 1,20 1,35 1,40
Lifetime Diagram UR < 160V
2.5
IA
––– 2.0
IR
CD 29L QL Series
1.5
1.0
0.5
0.0
20
X32 X16 X8 X4 X2 X1
Lifetime
Multiplier
30
40
50
60
70
80
90
TA (˚C)
IA = actual ripple current at 120Hz,
IR = rated ripple current at 120Hz, 85°C
Multiplier of Useful Life as a function of ambient temperature
and ripple current load
Lifetime Diagram UR ≥ 160V
2.5
IA
––– 2.0
IR
CD 29L QL Series
1.5
1.0
0.5
0.0
20
X32 X16 X8 X4 X2 X1
Lifetime
Multiplier
30
40
50
60
70
80
90
TA (˚C)
IA = actual ripple current at 120Hz,
IR = rated ripple current at 120Hz, 85°C
Multiplier of Useful Life as a function of ambient temperature
and ripple current load
64
Direct Contact & Support: Jianghai Europe GmbH +49 (0)2151-652088-0 info@jianghai-europe.com www.jianghai-europe.com