English
Language : 

CD29HQH Datasheet, PDF (1/4 Pages) Jianghai Europe GmbH – EC Snap-In 105°C Long Lifetime 5.000h Highest Ripple Currents Miniaturized(Snap-In)
CD 29H QH Series
5 000 h at 105°C
· Long Useful Life
· Highest Ripple Current
· Miniaturized
· Industrial Power Supplies and Inverters
CD 29H QH
highest
current
CD 299 PG
longest life
higher current
CD 294 BW
105°C
longer
life
CD 296 KC
longer
life
CD 297 BB
CD 293 BZ
Item
Operating Temperature Range (°C)
Voltage Range (V)
Capacitance Range (µF)
Capacitance Tolerance
(20°C, 120Hz)
Leakage Current (µA)
Characteristics
-40 ~ +105
160 ~ 450
47 ~ 2 200
± 20%
After 5 minutes at 20°C application of rated voltage, leakage
current is not more than 0,01CV or 1,5mA, whichever is smaller 
C: Nominal Capacitance (µF) V: Rated Voltage (V)
Rated Voltage (V)
160
Dissipation Factor (20°C, 120Hz)
Tan δ (max)
200
250
0,15
350
400
450
0,12
Stability at Low Temperature
(Impedance Ratio at 120Hz)
Rated Voltage (V)
Z -40°C / Z +20°C
160 ~ 450
4
Lifetime
Leakage Current
Capacity Change
Dissipation Factor
Condition:
Applied Voltage
Applied Current
Applied Temperature
Failure Rate Level
Useful Life
Load Life
Endurance Test
Shelf Life
5 000h
>100 000h
3 000h
3 000h
1 000h
Not more than specified value
Within ± 30% of initial value
Not more than 300% of specified value
Not more than specified Not more than specified
value
value
Within ± 20% of initial
value
Within ± 20% of initial
value
Not more than 200% of Not more than 130% of
specified value
specified value
Not more than specified
value
Within ± 20% of initial
value
Not more than 200% of
specified value
UR
IR
105°C
≤ 1% Failure Rate
UR
1,4 x IR
50°C
UR
IR
105°C
≤ 1% Failure Rate guaranteed
UR
IR = 0
105°C
UR = 0
IR = 0
105°C
After test:
UR to be applied
for 30min
>24h before
measurement
Multiplier for Ripple Current
Frequency Coefficient
Frequency
Coefficient
50Hz
0,87
120Hz
1,00
1kHz
1,15
10kHz 100kHz
1,35
1,40
Lifetime Diagram
3.0
IA
––– 2.5
IR
2.0
CD 29H QH Series
1.5
1.0
0.5
0.0
40
X32
Lifetime
Multiplier
50
X16
60
X8
70
X4
80
X2 X1
90
100 110
TA (˚C)
IA = actual ripple current at 120Hz, IR = rated ripple current at 120Hz, 105°C
Multiplier of Useful Life as a function of ambient temperature and ripple current load
62
Direct Contact & Support: Jianghai Europe GmbH +49 (0)2151-652088-0 info@jianghai-europe.com www.jianghai-europe.com
v2006.2