English
Language : 

CD263BK Datasheet, PDF (1/5 Pages) Jianghai Europe GmbH – EC Radial Standard 105°C 2.000 - 3.000h Lifetime(Radial)
CD 263 BK Series
2 000 - 3 000h at 105°C
· Standard 105°C
CD 110 PT
105°C
CD 269 PH
CD 11G GW
125°C
CD 263 BK
longer life
lower ESR
CD 287 GC
CD 261 LK
Item
Operating Temperature Range (°C)
Voltage Range (V)
Capacitance Range (µF)
Capacitance Tolerance (20°C, 120Hz)
-55 ~ +105
6,3 ~ 100
Characteristics
0,1 ~ 15 000
± 20%
-40 ~ +105
160 ~ 450
Leakage Current (µA)
Rated Voltage (V)
ILeakage (µA)
6,3 ~ 100
160 ~ 450
After 2 minutes at 20°C application of
rated voltage, leakage current is not more than
0,01CV or 3, whichever is greater.
After 1 minute at 20°C application of rated
voltage, leakage current is not more than:
CV ≤ 1.000 : 0,1 CV + 40
CV > 1.000 : 0,04 CV + 100
C: Nominal Capacitance (µF) V: Rated Voltage (V)
Dissipation Factor (20°C, 120Hz)
Rated Voltage (V) 6,3 10 16 25 35 50 63 100 160 200 250 350 400 450
Tan δ (max)
0,22 0,19 0,16 0,14 0,12 0,10 0,09 0,08
0,15
0,20
When nominal capacitance is over 1 000µF tan δ shall be added 0,02 to the listed value with increase of every 1 000µF
Stability at Low Temperature
(Impedance Ratio at 120Hz)
Rated Voltage (V) 6,3 10 16 25 35 50 63 100 160 200 250 350 400 450
Z -25°C / Z +20°C
Z -40°C / Z +20°C
43
864
2
3
3
8
6
Lifetime
Leakage Current
Capacity Change
Dissipation Factor
Condition:
Applied Voltage
Applied Current
Applied Temperature
Failure Rate Level
Useful Life
Ø ≤ 8 : 2 000h
Ø ≥ 10 : 3 000h
>100  000h
Not more than specified value
Within ± 30% of initial value
Not more than 300% of specified value
Load Life
Endurance Test
Shelf Life
Ø = 8 : 1 000h
Ø ≥ 10 : 2 000h
2 000h
1 000h
Not more than
specified value
Within ± 20% of initial
value
Not more than 200% of
specified value
Not more than specified
value
Within ± 20% of initial
value
Not more than 150% of
specified value
Not more than specified
value
Within ± 20% of initial
value
Not more than 200% of
specified value
UR
IR
105°C
≤ 1% Failure Rate
UR
1,4 x IR
40°C
≤ 1% Failure Rate
UR
IR
105°C
guaranteed
UR
IR = 0
105°C
UR = 0
IR = 0
105°C
After test:
UR to be applied
for 30min
>24h before
measurement
Multiplier for Ripple Current
Frequency Coefficient
Rated
Voltage (V)
Frequency
Capa-
citance
50Hz 120Hz 1kHz
(µF)
10kHz 100kHz
6,3 ~ 100
160 ~ 450
0,1 ~ 4,7
10 ~ 47
100 ~ 220
330 ~ 1 000
2 200 ~ 15 000
0,47 ~ 220
- 0,40 0,70 0,80 1,00
- 0,50 0,80 0,90 1,00
- 0,70 0,90 0,90 1,00
- 0,80 0,90 1,00 1,00
- 0,90 1,00 1,00 1,00
0,80 1,00 1,30 1,40 1,60
Lifetime Diagram 6,3 ~ 100V
2.5
IA
––– 2.0
IR
1.5
CD 263 BK Series
1.0
0.5
0.0
40
X32
Lifetime
Multiplier
50
X16 X8 X4 X2 X1
60
70
80
90
100 110
TA (˚C)
IA = actual ripple current at 100kHz,
IR = rated ripple current at 100kHz, 105°C
Multiplier of Useful Life as a function of ambient temperature
and ripple current load
Lifetime Diagram 160 ~ 450V
2.5
IA
––– 2.0
IR
1.5
CD 263 BK Series
1.0
0.5
0.0
40
X32
Lifetime
Multiplier
50
X16 X8 X4 X2 X1
60
70
80
90
100 110
TA (˚C)
IA = actual ripple current at 120Hz,
IR = rated ripple current at 120Hz, 105°C
Multiplier of Useful Life as a function of ambient temperature
and ripple current load
26
Direct Contact & Support: Jianghai Europe GmbH +49 (0)2151-652088-0 info@jianghai-europe.com www.jianghai-europe.com
v2006.2