English
Language : 

CD136PK Datasheet, PDF (1/4 Pages) Jianghai Europe GmbH – EC Screw Standard 105°C 4.000h Lifetime(Screw)
4 000h at 105°C
· Standard at 105°C
· Professional Power Supplies & Inverters
CD 136 PK Series
CD 136 PK
longer
life
CD 139 BL
105°C
CD 135 BP
longer
life
CD 138 PC
highest
voltage
CD 137 PX
Item
Operating Temperature Range (°C)
Voltage Range (V)
Capacitance Range (µF)
Capacitance Tolerance
(20°C, 120Hz)
Leakage Current (µA)
Dissipation Factor (20°C, 120Hz)
Stability at Low Temperature
(Impedance Ratio at 120Hz)
-40 ~ +105
25 ~ 100
Characteristics
220 ~ 330 000
-25 ~ +105
160 ~ 450
± 20%
After 5 minutes at 20°C application of rated voltage, leakage
current is not more than 0,01CV or 5mA, whichever is smaller 
C: Nominal Capacitance (µF) V: Rated Voltage (V)
Tan δ shall not exceed the values shown in the table of ratings
Capacitance change
25 - 100VDC : Capacitance at – 40°C shall not be less than 60% of the 20°C value
160 - 450VDC : Capacitance at – 25°C shall not be less than 70% of the 20°C value
Lifetime
Leakage Current
Capacity Change
Dissipation Factor
Condition:
Applied Voltage
Applied Current
Applied Temperature
Failure Rate Level
Useful Life
Load Life
Endurance Test
Shelf Life
4 000h
>200 000h
2 000h
2 000h
1 000h
Not more than specified value
Within ± 30% of initial value
Not more than 300% of specified value
Not more than specified Not more than specified
value
value
Within ± 20% of initial Within ± 10% of initial
value
value
Not more than 200% of Not more than 130% of
specified value
specified value
Not more than specified
value
Within ± 20% of initial
value
Not more than 200% of
specified value
UR
IR
105°C
≤ 1% Failure Rate
UR
1,2 x IR
40°C
UR
IR
105°C
≤ 1% Failure Rate guaranteed
UR
IR = 0
105°C
UR = 0
IR = 0
105°C
After test:
UR to be applied
for 30min
>24h before
measurement
Multiplier for Ripple Current
Frequency Coefficient
Frequency
Coefficient
50Hz
0,80
120Hz 300Hz
1,00
1,10
1kHz ≥10kHz
1,30 1,40
Lifetime Diagram
2.5
IA
––– 2.0
IR
CD 136 PK Series
1.5
1.0
0.5
0.0
40
X32 X16 X8 X4 X2 X1
Lifetime
Multiplier
50
60
70
80
90
100 110
TA (˚C)
IA = actual ripple current at 120Hz, IR = rated ripple current at 120Hz, 105°C
Multiplier of Useful Life as a function of ambient temperature and ripple current load
Direct Contact & Support: Jianghai Europe GmbH +49 (0)2151-652088-0 info@jianghai-europe.com www.jianghai-europe.com
v2006.2
69