English
Language : 

JH32240400E Datasheet, PDF (14/23 Pages) Jewel Hill Electronic – SPECIFICATIONS FOR LCD MODULE
JEWEL HILL ELECTRONIC CO.,LTD.
11.1. Sampling Method
Unless otherwise agreed upon in writing, the sampling inspection shall be applied to the
Customer’s incoming inspection.
1) Lot size: Quantity per shipment lot
2) Sampling type: Normal inspection , single sampling
3) Inspection level: Ⅱ
4) Sampling table: MIL-STD-105D
5) Acceptable Quality Level(AQL): Major=0.65 Minor=1.5
11.2. Inspection Method
1) Ambient Condition:
a. Temperature: Room temperature 25±5℃
b. Illumination: Single fluorescent lamp non-directive(300 to 700 Lux)
2) Viewing distance
The distance between the LCD and the inspector’s eyes shall be at least 30-50cm.
3) Viewing Angle
The inspection shall be conducted within normal viewing angle range.
11.3. Inspection Criteria
11.3.1. Major defect
No. Item
Inspection Standard
1) No display
All
2) Display abnormally
3) Open or missing segment
1
functional 4) Short circuit
defects 5) Excess power consumption
6) Backlight no lighting, flickering and abnormal lighting
2
Missing Missing component
Outline Overall outline dimension beyond the drawing is not
3
dimension allowed
Classification
of defects
Major
Major
Major
11.3.2. Cosmetic Defect
JH32240400E VER: 1.0
- 13 -
Issue date: 2013/08/12