Frequency Range
Configuration
Impedance
VSWR
Insertion Loss
Attenuation Range
Attenuation Accuracy
Isolation
RF Input Power
Switching Speed
AC Supply
Remote Control
Manual Control
JFW Industries, Inc.
Phone: 317-887-1340
sales@jfwindustries.com
www.jfwindustries.com
700-3000 MHz
4 x 8 Handover System
(unit is bi-directional)
See Block Diagram 092-6344
50 Ohms nominal
1.7:1 maximum
20 dB nominal @ 700 MHz
23 dB nominal @ 3000 MHz
0-127 dB in 1 dB steps
± 0.5 dB or 2% (nominal)
± 0.75 dB or 2% (maximum)
(whichever is greater)
(guaranteed monotonic)
40 dB minimum (Input to Input)
30 dB minimum (Output to Output)
+20 dBm average
5 microseconds typical
(after command is received and
processed)
(3 milliseconds typical processing time)
100-240 VAC @ 47-63 Hz
RS-232 (9600, 19200, or 38400 Baud)
Ethernet (TCP, 10/100, up to 4 users)
20-button keypad and backlit LCD display
Page 1 of 2
--CONTINUED--
JFW FORM E-7-F REV F