SPECIFICATION SHEET
JFW MODEL 50PA-393
HANDOVER TEST SYSTEM
Frequency Range
Configuration
Impedance
VSWR
Insertion Loss
Attenuation Range
Attenuation Accuracy
Power Divider Isolation
RF Input Power
Switching Speed
AC Supply
Manual Control
Remote Control
Remote Commands
Baud Rates (RS-232 mode)
RF Connector
Temperature Range
Physical Size
JFW Industries, Inc.
Phone: 317-887-1340
sales@jfwindustries.com
www.jfwindustries.com
800-2200 MHz
6 x 2 Handover Test System
See block diagram 092-5642
50 Ohms nominal
1.6:1 maximum
19.6 dB nominal
0-127 dB in 1 dB steps
± 0.4 dB or 2% of programmed
(whichever is greater)
25 dB minimum
+20 dBm
5 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
100-240 VAC @ 47-63 Hz
Keypad and LCD display
Ethernet (10/100) and RS-232
Set Attenuator (SAx y <CR>)
Read Attenuator (RAx <CR>)
Fade Attenuator (FAx y z t <CR>)
Handover
(HNDx y t)
Variable Handover (VHND Av Aw Vx Vy Tz)
Change Baud Rate (CBx <CR>)
Identification (IDN <CR>)
9600, 19200, or 38400 Baud
N female
0ºC to +50ºC
See outline drawing 092-5643
ECR/ECN # DATE
REV APPR / DATE
11/26/2007
TRS 11/26/2007
15916 05/28/2008 A TRS 05/28/2008
16179 08/07/2008 B TRS 08/07/2008
ECR/ECN # DATE
Page 1 of 1
JFW FORM E-7-F REV F
REV APPR / DATE