English
Language : 

50PA-392 Datasheet, PDF (1/2 Pages) JFW Industries, Inc. – LC HANDOVER TEST SYSTEM
SPECIFICATION SHEET
JFW MODEL 50PA-392
LC HANDOVER TEST SYSTEM
Frequency Range
Configuration
Impedance
VSWR
Attenuation Range
Insertion Loss
Attenuation Accuracy
Power Divider Isolation
RF Input Power
Switching Speed
AC Supply
Manual Control
Remote Control
Remote Commands
Baud Rates (RS-232 mode)
RF Connector
Temperature Range
Physical Size
JFW Industries, Inc.
Phone: 317-887-1340
sales@jfwindustries.com
www.jfwindustries.com
800-2200 MHz
6 x 1 LC Handover Test System
(See block diagram 092-5640)
50 Ohms nominal
1.6:1 maximum
0-127 dB in 1 dB steps
15.9 dB nominal
± 0.4 dB or 2% of programmed
(whichever is greater)
25 dB minimum
+20 dBm
5 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
100-240 VAC @ 47-63 Hz
Keypad and LCD display
Ethernet (10/100) and RS-232
Variable Handover (VHND Av Aw Vx Vy Tz)
Feedback Handover (FHND Av Aw Vx Vy Tz)
Fade Attenuator (FAx y z t <CR>)
Feedback Fade
(FFAx y z t <CR>)
Pause
(PAUSEx)
Set Attenuator (SAx y <CR>)
Read Attenuator (RAx <CR>)
Change Baud Rate (CBx <CR>)
Identification (IDN <CR>)
9600, 19200, or 38400 Baud
N female
0ºC to +50ºC
See outline drawing 092-5641
Page 1 of 2
--CONTINUED--
JFW FORM E-7-F REV F