English
Language : 

50PA-389 Datasheet, PDF (1/2 Pages) JFW Industries, Inc. – HANDOVER TEST SYSTEM
SPECIFICATION SHEET
JFW MODEL 50PA-389
HANDOVER TEST SYSTEM
Frequency Range
Configuration
Impedance
VSWR
Insertion Loss
Attenuation Range
Attenuation Accuracy
(guaranteed monotonic)
Power Divider Isolation
RF Input Power
Switching Speed
AC Supply
Manual Control
Remote Control
Remote Commands
Baud Rates (RS-232 mode)
RF Connector
Temperature Range
Physical Size
JFW Industries, Inc.
Phone: 317-887-1340
sales@jfwindustries.com
www.jfwindustries.com
800-3000 MHz
12 x 4 Handover Test System
See block diagram 092-5634
50 Ohms nominal
1.5:1 typical
1.7:1 maximum
29.2 dB typical @ 800 MHz
33.7 dB typical @ 3000 MHz
0-127 dB in 1 dB steps
± 0.5 dB or 2% (typical)
± 0.75 dB or 2% (maximum)
20 dB minimum
+25 dBm operating
+30 dBm (no damage)
10 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
100-240 VAC @ 47-63 Hz
Keypad and LCD display
Ethernet (10/100) and RS-232
Set Attenuator (SAx y <CR>)
Read Attenuator (RAx <CR>)
Fade Attenuator (FAx y z t <CR>)
Handover
(HNDx y t)
Variable Handover (VHND Av Aw Vx Vy Tz)
Change Baud Rate (CBx <CR>)
9600, 19200, or 38400 Baud
SMA female
0ºC to +50ºC
See outline drawing 092-5635
Page 1 of 2
--CONTINUED--
JFW FORM E-7-F REV F