English
Language : 

LPR-530DWC1SA Datasheet, PDF (2/3 Pages) JDS Uniphase Corporation – WaveReady™ 3000 Series Path and Equipment Protection Switch
2
Typical Application
WAVEREADY 3000 SERIES
Port A
Port B
50/50 Splitter Port C
Port E
Primary Path
Secondary Path
Port D
Port F
Switch
Port D
Port F
Primary Path
Secondary Path
Port C
Port E
Switch
Port B
50/50 Splitter
Port A
Specifications
Parameter
Minimum
Typical
Maximum
General Optical Characteristics
Wavelength for all ports
Switch Optical Characteristics
Insertion loss (including connectors)
Return loss (including connectors)
Switching time
Window switching mode
Reference power level range (RPLR)
RPL accuracy
Upper window switching range (UWSR)
(user programmable, settable in 1 dB increments)
Lower window switching range (LWSR)
(user programmable, settable in 1 dB increments)
Upper window switching limit (UWSL) (UWSL = RPL + UWSR)
Lower window wwitching limit (LWSL) (LWSL = RPL - LWSR)
Auto-switch-back hysteresis
Switch-back hold time
Switch type
Received power monitor accuracy (Received power range: -35 to 0 dBm)
Maximum received power level (no damage to the module)
Coupler Optical Characteristics
Insertion loss (including connectors)
Return loss (including connectors)
Electrical Characteristics
DC supply voltage (Through the DenseMount Shelf.
The DC power supply must be certified by a nationally
recognizedtest laboratory (NRTL) with -48 V SELV output.)
Power dissipation
Alarm relay signals
-
>40 dB
-
≥-29 dBm
-
-
-
-
≥-35 dBm
2 dB
3s
Latching
-
-
-
>40 dB
-
-
1290 to 1350 nm and 1463 to 1630 nm
-
<2 dB
-
-
-
<15 ms
-
±2 dB
≥6 dB
≤-6 dBm
-
-
≥6 dB
-
-
-
-
-
-
±2 dB
-
≤0 dBm
-
-
-
-
-
<15 dBm
-
<4 dB
-
-
-48 V
-
-
2W
Dry contact. Relay closed when alarm is active.