English
Language : 

MIXA60WB1200TEH Datasheet, PDF (7/8 Pages) IXYS Corporation – Converter - Brake - Inverter
MIXA60WB1200TEH
Inverter D1 - D6
120
100
80
IF
60
[A]
40
20
TVJ = 125°C
TVJ = 25°C
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
VF [V]
Fig. 7 Typ. Forward current versus VF
14
12
10
Qrr 8
[µC] 6
4
TVJ = 125°C
VR = 600 V
120 A
60 A
30 A
2
600 700 800 900 1000 1100 1200 1300
diF /dt [A/µs]
Fig. 8 Typ. reverse recov.charge Qrr vs. di/dt
90
80
70
60
IRR
50
TVJ = 125°C
VR = 600 V
120 A
60 A
30 A
[A] 40
30
20
10
0
600 700 800 900 1000 1100 1200 1300
diF /dt [A/µs]
Fig. 9 Typ. peak reverse current IRM vs. di/dt
700
600
TVJ = 125°C
VR = 600 V
500
trr 400
[ns] 300
200
120 A
60 A
30 A
100
0
600 700 800 900 1000 1100 1200
diF /dt [A/µs]
Fig. 10 Typ. recovery time trr versus di/dt
1300
4.0
TVJ = 125°C
VR = 600 V
3.2
1
120 A
Diode
IGBT
Erec 2.4
60 A
[mJ]
1.6
30 A
0.8
0.0
600 700 800 900 1000 1100 1200 1300
diF /dt [A/µs]
Fig. 8 Typ. recovery energy Erec versus di/dt
ZthJC 0.1
[K/W]
IGBT
FRD
Ri
1 0.1
ti
Ri
ti
0.002 0.137 0.002
2 0.05 0.03 0.1 0.03
3 0.21 0.03 0.233 0.03
0.01
0.001
4 0.07 0.08 0.13
0.01
0.1
1
0.08
10
tp [s]
Fig. 9 Typ. transient thermal impedance
IXYS reserves the right to change limits, test conditions and dimensions.
20110916e
© 2011 IXYS All rights reserved
7-8