English
Language : 

CPC7601 Datasheet, PDF (6/11 Pages) IXYS Corporation – Low Charge Injection, 16-Channel High Voltage Analog Switch
INTEGRATED CIRCUITS DIVISION
CPC7601
1.5.2 Logic Timing Characteristics
(Over recommended operating conditions unless otherwise noted.)
Parameter
Symbol
Test Conditions
Setup Time Before LE Rises tSD
-
Time Width of LE
tWLE
VDD=3V
VDD=5V
Clock Delay Time to Data Out
tDO
VDD=3V
VDD=5V
Time Width of CL
tWCL
-
Setup Time, Data to Clock
tsu
VDD=3V
VDD=5V
Hold Time, Data from Clock
th
-
Clock Frequency
fCLK
50% duty cycle, fDATA= ½ fCLK, VDD=3V
50% duty cycle, fDATA= ½ fCLK, VDD=5V
Clock Rise and Fall Times
tr , tf
-
Turn-On Time
Turn-Off Time
ton
toff
VSIG=VPP-10V, RL=10k
0°C
min max
25
-
56
-
12
-
10 100
5 45
55
-
21
-
7
-
2
-
-
8
-
20
-
50
-
5
-
5
+25°C
min typ max
25
-
-
56
-
-
12
-
-
10
-
100
5
-
45
55
-
-
-
21
-
-
7
-
2
-
-
-
-
8
-
-
20
-
-
50
-
-
5
-
5
70°C
Units
min max
25
-
56
-
12
-
10 100
5 45 ns
55
-
21
-
7
-
2
-
-
8
MHz
-
20
-
50 ns
-
5
s
-
5
1.5.3 Logic Timing Waveforms
D
D
N-1
N
D
N+1
D
IN
50%
50%
LE
CLK
D
OUT
OFF
VOUT
ON
50%
tsu
50%
t
WLE
t
SD
50%
t
DO
th
50%
toff
90%
CL 50%
50%
tWCL
50%
ton
10%
6
www.ixysic.com
R02