English
Language : 

CPC7583_12 Datasheet, PDF (6/19 Pages) IXYS Corporation – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
CPC7583
1.6.2 Ringing Return Switch, SW3
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Off-state leakage current
+25° C
VSW (differential) = -320 V to gnd
VSW (differential) = +260 V to -60 V
+85° C
VSW (differential) = -330 V to gnd
VSW (differential) = +270 V to -60 V
ISW
-
-40° C
VSW (differential) = -310 V to gnd
VSW (differential) = +250 V to -60 V
RON
+25° C
+85° C
ISW(on) = ±0 mA, ±10 mA
RON
-
-40° C
DC current limit
0.1
0.3
1
A
0.1
60
-
85
110

45
-
+25° C
-
120
+85° C
VSW (on) = ± 10 V
70
85
mA
-40° C
ISW
210
-
Dynamic current limit
(t 0.5 s)
Break switches off, ringing switches on,
apply ±1 kV 10x1000 s pulse, with
appropriate protection in place.
-
2.5
A
Logic input to switch output isolation
+25° C
VSW (TRING, TLINE) = ±320 V, logic
0.1
inputs = gnd
+85° C
VSW (TRING, TLINE) = ±330 V, logic
inputs = gnd
ISW
-
0.3
1
A
-40° C
VSW (TRING, TLINE) = ±310 V, logic
inputs = gnd
dv/dt sensitivity
-
-
0.1
-
200
-
V/s
6
www.ixysic.com
R07