English
Language : 

LCA710 Datasheet, PDF (4/7 Pages) Clare, Inc. – Single Pole OptoMOS Relay
INTEGRATED CIRCUITS DIVISION
LCA710
PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
-40
Typical Turn-On Time
vs. Temperature
(IL=1ADC)
IF=5mA
IF=10mA
-20 0 20 40 60 80 100
Temperature (ºC)
0.14
0.12
0.10
0.08
0.06
0.04
0.02
0
-40
Typical Turn-Off Time
vs. Temperature
(IL=1ADC)
IF=10mA
IF=5mA
-20 0 20 40 60 80 100
Temperature (ºC)
Typical IF for Switch Operation
vs. Temperature
(IL=1ADC)
1.01
1.00
0.99
0.98
0.97
0.96
0.95
0.94
0.93
0.92
0
-40 -20 0
20 40 60
80 100
Temperature (ºC)
Typical On-Resistance
vs. Temperature
(IF=10mA, IL=1ADC)
0.45
Typical Load Current
vs. Load Voltage
(IF=10mA)
1000
0.40
800
0.35
600
0.30
400
200
0.25
0
0.20
-200
0.15
-400
0.10
-600
0.05
-800
0
-1000
-40 -20 0 20 40 60 80 100
-0.3 -0.2 -0.1
0
0.1 0.2 0.3
Temperature (ºC)
Load Voltage (V)
Maximum Load Current
vs. Temperature
1400
1200
1000
IF=10mA
800
600
IF=5mA
400
200
0
-40 -20
0 20 40 60 80 100 120
Temperature (ºC)
Typical Blocking Voltage
vs. Temperature
81.0
80.0
79.0
78.0
77.0
76.0
75.0
74.0
73.0
-40 -20
0 20 40 60
Temperature (ºC)
80 100
Typical Leakage vs. Temperature
Measured Across Pins 4&6
0.019
0.018
0.017
0.016
0.015
0.014
0.013
0
-40 -20
0 20 40 60
Temperature (ºC)
80 100
Energy Rating Curve
8
7
6
5
4
3
2
1
0
10Ps 100Ps 1ms 10ms 100ms 1s
Time
10s 100s
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
4
www.ixysic.com
R09