English
Language : 

LCB716 Datasheet, PDF (3/7 Pages) Clare, Inc. – Single Pole OptoMOS® Relay
INTEGRATED CIRCUITS DIVISION
LCB716
PERFORMANCE DATA* (@25ºC Unless Otherwise Noted)
Typical LED Forward Voltage Drop
(N=50, IF=5mA)
30
25
20
15
10
5
0
1.220 1.225 1.230 1.235 1.240 1.245
LED Forward Voltage Drop (V)
Typical Turn-On Time
(N=50, IF=5mA, IL=100mA)
20
15
10
5
0
0.507 0.530 0.553 0.576 0.599 0.622
Turn-On Time (ms)
Typical Turn-Off Time
(N=50, IF=5mA, IL=100mA)
25
20
15
10
5
0
0.63 0.67 0.71 0.75 0.79 0.83
Turn-Off Time (ms)
Typical IF for Switch Operation
(N=50, IL=200mA)
25
20
15
10
5
0
0.16 0.17 0.18 0.19 0.20 0.21
LED Forward Current (mA)
Typical On-Resistance
(N=50, IF=0mA, IL=5mA)
20
15
10
5
0
1.49 1.53 1.57 1.61 1.65 1.69
On-Resistance (:)
Typical IF for Switch Operation
vs. Temperature
(IL=100mA)
0.40
Typical Turn-On Time
vs. LED Forward Current
(IL=100mA)
423
0.35
422
0.30
421
0.25
420
0.20
419
0.15
418
0.10
-40 -20
0 20 40 60
Temperature (ºC)
80 100
417
0
10
20
30
40
50
LED Forward Current (mA)
Typical Blocking Voltage
(N=50, IF=2mA)
20
15
10
5
0
75 76 77 78 79 80
Blocking Voltage (VP)
Typical Turn-Off Time
vs. LED Forward Current
(I =100mA)
L
2.5
2.0
1.5
1.0
0.5
0
0
10
20
30
40
50
LED Forward Current (ma)
Typical Turn-On Time
vs. Temperature
(IL=100mA)
800
700
600
500
400
300
IF=2mA
200
IF=5mA
100
-40 -20
0 20 40 60
Temperature (ºC)
80 100
Typical Turn-Off Time
vs. Temperature
(IL=100mA)
4.5
4.0
3.5
3.0
IF=2mA
2.5
2.0
1.5
1.0
IF=5mA
0.5
-40 -20
0 20 40 60
Temperature (ºC)
80 100
Typical On-Resistance
vs. Temperature
1.8
(IF=0mA, IL=100mA)
1.7
1.6
1.5
1.4
1.3
1.2
1.1
-40 -20
0 20 40 60
Temperature (ºC)
80 100
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
R03
www.ixysic.com
3