English
Language : 

LAA126_12 Datasheet, PDF (3/7 Pages) IXYS Corporation – Dual Single-Pole, Normally Open OptoMOS Relays
INTEGRATED CIRCUITS DIVISION
LAA126
PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
Typical LED Forward Voltage Drop
(N=50, IF=5mA)
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
Typical Turn-On Time
(N=50, IF=5mA, IL=170mADC)
25
20
15
10
5
0
0.625 0.875 1.125 1.375 1.625 1.875 2.125
Turn-On Time (ms)
Typical Turn-Off Time
(N=50, IF=5mA, IL=170mADC)
25
20
15
10
5
0
0.05 0.15 0.25 0.35 0.45 0.55 0.65
Turn-Off Time (ms)
Typical IF for Switch Operation
(N=50, IL=170mADC)
25
20
15
10
5
0
0.3 0.5 0.7 0.9 1.1 1.3 1.5
LED Current (mA)
Typical IF for Switch Dropout
(N=50, IL=170mADC)
25
20
15
10
5
0
0.15
0.45 0.75 1.05 1.35 1.65 1.95
LED Forward Current (mA)
Typical On-Resistance Distribution
(N=50, IF=5mA, IL=170mADC)
35
30
25
20
15
10
5
0
6.5
7.5
8.5
9.5
10.5
On-Resistance (:)
Typical LED Forward Voltage Drop
vs. Temperature
1.8
1.6
1.4
IF=50mA
IF=30mA
1.2
IF=20mA
IF=10mA
1.0
IF=5mA
0.8
-40 -20
0 20 40 60 80 100 120
Temperature (ºC)
Typical Blocking Voltage Distribution
(N=50)
35
30
25
20
15
10
5
0
305 315 325 335 345 355 365
Blocking Voltage (VP)
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
Typical Turn-On Time
vs. LED Forward Current
(IL=170mADC)
5 10 15 20 25 30 35 40 45 50
LED Forward Current (mA)
0.41
0.40
0.39
0.38
0.37
0.36
0.35
0.34
0
Typical Turn-Off Time
vs. LED Forward Current
(IL=170mADC)
5 10 15 20 25 30 35 40 45 50
LED Forward Current (mA)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
R05
www.ixysic.com
3