English
Language : 

MIXA40WB1200TED Datasheet, PDF (2/8 Pages) IXYS Corporation – Converter - Brake - Inverter
MIXA40WB1200TED
Ouput Inverter T1 - T6
Symbol
VCES
VGES
VGEM
IC25
IC80
Definitions
collector emitter voltage
max. DC gate voltage
max. transient collector gate voltage
collector current
Ptot
VCE(sat)
total power dissipation
collector emitter saturation voltage
VGE(th)
ICES
gate emitter threshold voltage
collector emitter leakage current
IGES
QG(on)
td(on)
tr
td(off)
tf
Eon
Eoff
RBSOA
gate emitter leakage current
total gate charge
turn-on delay time
current rise time
turn-off delay time
current fall time
turn-on energy per pulse
turn-off energy per pulse
reverse bias safe operating area
SCSOA
tSC
ISC
RthJC
short circuit safe operating area
short circuit duration
short circuit current
thermal resistance junction to case
Conditions
continuous
transient
TVJ = 25°C
TC = 25°C
TC = 80°C
min.
Ratings
typ. max. Unit
1200 V
±20 V
±30 V
60 A
40 A
TC = 25°C
IC = 35 A; VGE = 15 V
TVJ = 25°C
TVJ = 125°C
IC = 1.5 mA; VGE = VCE
TVJ = 25°C
VCE = VCES; VGE = 0 V
TVJ = 25°C
TVJ = 125°C
VGE = ±20 V
VCE = 600 V; VGE = 15 V; IC = 35 A
inductive load
VCE = 600 V; IC = 35 A
VGE = ±15 V; RG = 27 W
TVJ = 125°C
VGE = ±15 V; RG = 27 W;
TVJ = 125°C
VCEK = 1200 V
195 W
1.8 2.1 V
2.1
V
5.4 6.0 6.5 V
2.1 mA
0.2
mA
500 nA
106
nC
70
ns
40
ns
250
ns
100
ns
3.8
mJ
4.1
mJ
105 A
VCE = 900 V; VGE = ±15 V;
RG = 27 W; non-repetitive
(per IGBT)
TVJ = 125°C
10 µs
140
A
0.64 K/W
Output Inverter D1 - D6
Symbol
VRRM
IF25
IF80
VF
Definitions
max. repetitve reverse voltage
forward current
forward voltage
Qrr
IRM
trr
Erec
RthJC
reverse recovery charge
max. reverse recovery current
reverse recovery time
reverse recovery energy
thermal resistance junction to case
Conditions
IF = 30 A; VGE = 0 V
VR = 600 V
diF /dt = -600 A/µs
IF = 30 A; VGE = 0 V
(per diode)
Ratings
min. typ. max.
TVJ = 25°C
TC = 25°C
TC = 80°C
TVJ = 25°C
TVJ = 125°C
TVJ = 125°C
1200
44
29
1.95 2.2
1.95
3.5
30
350
0.9
1.2
TC = 25°C unless otherwise stated
Unit
V
A
A
V
V
µC
A
ns
mJ
K/W
IXYS reserves the right to change limits, test conditions and dimensions.
© 2011 IXYS All rights reserved
20110916e
2-8