English
Language : 

LCB110 Datasheet, PDF (2/7 Pages) Clare, Inc. – Single Pole OptoMOS Relay
INTEGRATED CIRCUITS DIVISION
LCB110
Absolute Maximum Ratings @ 25ºC
Parameter
Ratings
Units
Blocking Voltage
Reverse Input Voltage
350
VP
5
V
Input Control Current
50
mA
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
1
A
150
mW
800
mW
Isolation voltage, Input to Output
Operational Temperature
3750
Vrms
-40 to +85
°C
Storage Temperature
-40 to +125
°C
1 Derate linearly 3.33 mW / ºC
1 Derate linearly 6.67 mW / ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Load Current Continuous
AC/DC Configuration
DC Configuration
Peak Load Current
On-Resistance
-
t=10ms
IL
-
-
120
mArms / mADC
200
mADC
IL
-
-
±350
mAP
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
IL=120mA
IL=200mA
RON
-
23
35
-
7
10

IF=5mA, VL=350VP
ILEAK
-
-
1
A
Turn-On
Turn-Off
IF=5mA, VL=10V
ton
toff
-
0.38
3
ms
-
0.93
3
Output Capacitance
IF=5mA, VL=50V, f=1MHz
COUT
-
25
-
pF
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
IL=120mA
-
IF=5mA
VR=5V
IF
-
-
5
mA
IF
0.4
0.7
-
mA
VF
0.9
1.2
1.4
V
IR
-
-
10
A
Input to Output Capacitance
-
CI/O
-
3
-
pF
2
www.ixysic.com
R09