Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Ratings
250
5
50
1
150
800
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Load Current
AC/DC Configuration, Continuous
DC Configuration, Continuous
Load Current Limiting
On-Resistance 1
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Conditions
Symbol
Min
Typ
Max
Units
-
-
IL
-
ICL
IL=Load Current
IL=Load Current
RON
VL=250VP
ILEAK
-
-
150
mArms & mADC
-
-
200
mADC
190
235
280
mA
-
15
20

-
5
6
-
-
1
µA
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
IF = 5mA, VL = 10V
ton
toff
-
-
3
-
-
3
ms
ms
VL=50V, f=1MHz
COUT
-
50
-
pF
Input Control Current to Activate
IL = Load Current
IF
-
-
5
mA
Input Control Current to Deactivate
-
IF
0.4
0.7
-
mA
Input Voltage Drop
IF = 5mA
VF
0.9
1.2
1.4
V
Reverse Input Current
VR = 5V
IR
-
-
10
µA
Common Characteristics
Capacitance, Input to Output
-
CI/O
-
3
-
pF
1 Measurement taken within 1 second of on-time.
2
www.ixysic.com