Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Ratings
250
5
Units
VP
V
Input Control Current
50
mA
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
1
A
150
mW
800
mW
Isolation Voltage, Input to Output 3750
Vrms
Operational Temperature
-40 to +85 °C
Storage Temperature
-40 to +125 °C
1 Derate linearly 1.33 mW / °C
2 Derate linearly 6.67 mW / °C
LAA127
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Conditions
Symbol
Min
Typ
Max
Load Current
Continuous 1
Peak
On-Resistance 2
Off-State Leakage Current
Switching Speeds
-
IL
t =10ms
ILPK
IL=200mA
RON
VL=250VP
ILEAK
-
-
200
-
-
±400
-
6.8
10
-
-
1
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
IF=5mA, VL=10V
ton
toff
VL=50V, f=1MHz
COUT
-
0.39
5
-
0.15
5
-
110
-
Input Control Current to Activate
Input Control Current to Deactivate
IL=200mA
IF
-
-
5
-
-
0.4
0.5
-
Input Voltage Drop
Reverse Input Current
Common Characteristics
IF=5mA
VR=5V
VF
0.9
1.2
1.4
IR
-
-
10
Input to Output Capacitance
-
CI/O
-
3
-
1 If both poles operate, the load current must be derated so as not to exceed the package power dissipation value.
2 Measurement taken within one (1) second of on-time.
Units
mArms / mADC
mAP

A
ms
pF
mA
mA
V
A
pF
2
www.ixysic.com
R11