English
Language : 

LAA125L Datasheet, PDF (2/7 Pages) Clare, Inc. – Single Pole OptoMOS Relays
INTEGRATED CIRCUITS DIVISION
LAA125L
Absolute Maximum Ratings @25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Ratings
350
5
50
1
150
800
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @25ºC (Unless Otherwise Noted)
Parameter
Output Characteristics
Load Current, Continuous 1
Peak Load Current
Load Current Limiting
On-Resistance 2
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Input to Output Capacitance
Conditions
Symbol
Min
Typ
-
IL
10ms max
ILPK
-
ICL
IL=Load Current
RON
VL=350VP
ILEAK
IF=5mA, VL=10V
ton
toff
50V, f=1MHz
COUT
IL=170mA
IF
-
-
IF=5mA
VF
VR=5V
IR
-
CI/O
-
-
-
-
±190
±235
-
-
-
-
-
-
-
-
-
50
-
-
0.4
0.7
0.9
1.2
-
-
-
3
1 If both poles operate, then the load current must be derated so that it does not exceed the package power dissipation value.
2 Measurement taken within one second of on-time.
Max
150
±400
±280
18
1
5
5
-
5
-
1.4
10
-
Units
mArms / mADC
mAP
mA

A
ms
pF
mA
mA
V
A
pF
2
www.ixysic.com
R11