English
Language : 

LAA120_12 Datasheet, PDF (2/7 Pages) IXYS Corporation – Dual Single-Pole, Normally Open OptoMOS Relay
INTEGRATED CIRCUITS DIVISION
Absolute Maximum Ratings @ 25°C
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1 Derate linearly 1.33 mW / °C
2 Derate linearly 6.67 mW / °C
Ratings
250
5
50
1
150
800
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
LAA120
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25°C
Parameter
Output Characteristics
Conditions
Symbol
Min
Typ
Load Current
Continuous 1
Peak
On-Resistance 2
Off-State Leakage Current
Switching Speeds
-
IL
t = 10ms
ILPK
IL=170mA
RON
VL=250VP
ILEAK
-
-
-
-
-
15
-
-
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
IF=5mA, VL=10V
ton
toff
VL=50V, f=1MHz
COUT
-
-
-
-
-
50
Input Control Current to Activate
Input Control Current to Deactivate
IL=170mA
IF
-
-
-
-
0.4
0.7
Input Voltage Drop
Reverse Input Current
Common Characteristics
IF=5mA
VR=5V
VF
0.9
1.2
IR
-
-
Input to Output Capacitance
-
CI/O
-
3
1 If both poles operate, then the load current must be derated so that it does not exceed the package power dissipation value.
2 Measurement taken within 1 second of on-time.
Max
170
±400
20
1
5
5
-
5
-
1.4
10
-
Units
mArms / mADC
mAP

A
ms
pF
mA
mA
V
A
pF
2
www.ixysic.com
R09