Absolute Maximum Ratings @ 25°C
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1 Derate linearly 1.33 mW / °C
2 Derate linearly 6.67 mW / °C
Ratings
350
5
50
1
150
800
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
LAA110
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25°C
Parameter
Output Characteristics
Load Current, Continuous 1
Peak Load Current
On-Resistance 2
Off-State Leakage Current
Switching Speeds
Conditions
Symbol
Min
-
IL
-
t=10ms
ILPK
-
IL=120mA
RON
-
VL=350VP
ILEAK
-
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
IF=5mA, VL=10V
ton
toff
-
-
VL=50V, f=1MHz
COUT
-
Input Control Current to Activate
Input Control Current to Deactivate
IL=120mA
IF
-
-
-
0.4
Input Voltage Drop
Reverse Input Current
Common Characteristics
IF=5mA
VR=5V
VF
0.9
IR
-
Input to Output Capacitance
-
CI/O
-
1 If both poles operate the load current must be derated so as not to exceed the package power dissipation value.
2 Measurement taken within 1 second of on-time.
Typ
Max
-
120
-
±350
25
35
-
1
-
3
-
3
25
-
-
5
0.7
-
1.2
1.4
-
10
3
-
Units
mArms / mADC
mAP

A
ms
ms
pF
mA
mA
V
A
pF
2
www.ixysic.com
R11