Absolute Maximum Ratings @ 25ºC
Parameter
Ratings Units
Blocking Voltage
Reverse Input Voltage
600
VP
5
V
Input Control Current
Peak (10ms)
Input Power Dissipation 1
PD, Total Package Dissipation 2
100
mA
1
A
150
mW
1600 mW
Isolation Voltage, Input to Output
Operational Temperature
3750
Vrms
-40 to +85 °C
Storage Temperature
-40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 16.6 mW / ºC
CPC1965Y
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameters
Conditions
Symbol
Min
Typ Max Units
Output Characteristics
Operating Voltage Range
Load Current, Continuous
Non-Repetitive Single Cycle Surge Current
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
VL
-
20
-
VL=120-260Vrms
IL
0.005
-
-
ITSM
-
-
VL=600VP
ILEAK
-
-
IL=1Arms
-
-
-
-
dV/dt
1000
-
260
Vrms
1.0
Arms
10
A
1
mA
1.6
Vrms
-
V/µs
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage 1
IF=5 mA
ton
-
-
0.5
cycles
toff
-
-
0.5
1st half-cycle
-
-
2
10
V
Subsequent half-cycle
-
-
1
-
V
Operating Frequency
-
-
20
-
400
Hz
Load Power Factor for Guaranteed Turn-On 2
-
PF
0.25
-
-
-
Input Characteristics
Input Control Current to Activate 4
Input Voltage Drop
Input Drop-out Voltage
-
IF=5mA
-
IF
-
0.8
5
mA
VF
0.9
1.2
1.4
V
-
0.8
-
-
V
Reverse Input Current
Common Characteristics
VR=5V
IR
-
-
10
µA
Input to Output Capacitance
-
1 Zero Cross 1st half-cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments, use IF=10mA.
CI/O
-
3
-
pF
2
www.ixysic.com
R07