English
Language : 

CPC1965G Datasheet, PDF (2/6 Pages) Clare, Inc. – AC Solid State Relay
INTEGRATED CIRCUITS DIVISION
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
PD , Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Ratings
600
5
100
1
150
1600
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 16.6 mW / ºC
CPC1965G
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameters
Conditions
Symbol Min
Typ Max Units
Output Characteristics
Operating Voltage Range
Load Current, Continuous
Non-Repetitive Single Cycle Surge Current
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
VL
-
20
-
260
Vrms
VL=120-260Vrms
IL
0.005
-
1.0
Arms
-
ITSM
-
-
10
A
VL=600VP
ILEAK
-
-
1
mA
IL=1Arms
-
-
1.6
Vrms
-
dV/dt
1000
-
-
V/µs
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage 1
IF=5 mA
ton
-
-
0.5
cycles
toff
-
-
0.5
1st half-cycle
-
-
2
10
V
Subsequent half-cycle
-
-
1
-
V
Operating Frequency
-
-
20
-
400
Hz
Load Power Factor for Guaranteed Turn-On 2
-
PF
0.25
-
-
-
Input Characteristics
Input Control Current to Activate 4
Input Voltage Drop
Input Drop-out Voltage
-
IF=5mA
-
IF
-
0.8
5
mA
VF
0.9
1.2
1.4
V
-
0.8
-
-
V
Reverse Input Current
Common Characteristics
VR=5V
IR
-
-
10
µA
Input to Output Capacitance
-
1 Zero Cross 1st half-cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments, use IF=10mA.
CI/O
-
3
-
pF
2
www.ixysic.com
R07