Absolute Maximum Ratings
Parameter
Reverse Voltage
Ratings
10
Operational Temperature
-40 to +85
Storage Temperature
-40 to +125
Electrical absolute maximum ratings are at 25°C
Units
V
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max Units
Output Characteristics @ 25°C
Open Circuit Voltage
Short Circuit Current
Direct Sun (6000 lux)
VOC
High Intensity Lamp
VOC
Direct Sun (6000 lux)
ISC
-
8.5
-
V
-
10
-
V
-
50
-
A
PERFORMANCE DATA*
Normalized Open Circuit Output Voltage
vs. Light Intensity
16
14
12
10
8
6
4
2
0
0
2
4
6
8
10
Light Intensity (lux X 1000)
Normalized Short Circuit Output Current
vs. Light Intensity
200
180
160
140
120
100
80
60
40
20
0
0
2
4
6
8
10
Light Intensity (lux X 1000)
Normalized Open Circuit Output Voltage
vs. Incident Angle of Light
to Photodiode Surface
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
20
40
60
80
100
Incident Angle (Degrees)
Normalized Short Circuit Output Current
vs. Incident Angle of Light
to Photodiode Surface
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
20
40
60
80
100
Incident Angle (Degrees)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please