CPC7232_12 Datasheet, PDF (10/14 Pages) IXYS Corporation – 8-Channel HV Analog Switch with Built-in Bleeder Resistors
INTEGRATED CIRCUITS DIVISION
PRELIMINARY
2.1 Truth Table
D0 D1 D2 D3 D4 D5 D6 D7 LE CL SW0 SW1 SW2 SW3 SW4 SW5 SW6 SW7
L
L L OFF
H
L L ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L LL
OFF
HLL
ON
X XXX X XXX H L
HOLD PREVIOUS STATE
X X X X X X X X X H OFF OFF OFF OFF OFF OFF OFF OFF
Notes:
1. The eight switches operate independently.
2. Serial data is clocked in on the rising edge of the CLOCK signal.
3. The switches go to a state retaining their present condition at the rising edge of LE. When LE is low the shift
register data flows through the latch.
4. DOUT is high when switch 7 is on.
5. Shift register clocking has no effect on the switch states if LE is H.
6. The clear input overrides all other inputs.
CPC7232
10
PRELIMINARY
R00J