VWO 85
Three Phase
AC Controller Modules
IRMS = 3x 83 A
VRRM = 800-1600 V
Preliminary data
VRSM
VDSM
V
800
1200
1400
1600
VRRM
VDRM
V
800
1200
1400
1600
Type
VWO 85-08io1
VWO 85-12io1
VWO 85-14io1
VWO 85-16io1
C1 E1 K1 M1 S1 V1
C10 E10 K10 M10 S10V10
Symbol
IRMS
IRMS
ITAVM
I
TSM
I2t
(di/dt)cr
(dv/dt)cr
PGM
PGAVM
VRGM
TVJ
TVJM
Tstg
VISOL
Md
Weight
Test Conditions
Max. Ratings per phase
TC = 85°C, 50 - 400 Hz (per phase)
TC = 85°C, 50 - 400 Hz (per phase) for 10 sec.
TC = 85°C; (180° sine)
T
VJ
=
45°C;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 125°C
V =0
R
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 125°C
V =0
R
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ=125°C
repetitive, IT = 45 A
f =50 Hz, tP =200 ms
VD = 2/3 VDRM
IG = 0.45 A
non repetitive, IT = ITAVM
di /dt
G
=
0.45
A/ms
TVJ=125°C;
VDR = 2/3 VDRM
RGK = ¥; method 1 (linear voltage rise)
TVJ=125°C
IT = ITAVM
tp = 30 ms
tp = 300 ms
59
83
27
520
560
470
510
1350
1320
1100
1090
150
A
A
A
A
A
A
A
A2s
A2s
A2s
A2s
A/ms
500 A/ms
1000 V/ms
10
W
5
W
0.5
W
for 10 sec.
50/60 Hz, RMS
t = 1 min
I
ISOL
£
1
mA
t=1s
Mounting torque (M5)
10
-40...+125
150
-40...+125
3000
3600
2-2.5
18-22
V
°C
°C
°C
V~
V~
Nm.
lb.in.
typ.
80
g
Features
q Thyristor controller for AC (circuit
W3C acc. to IEC) for mains
frequency
q Package with DCB base plate
q Isolation voltage 3600 V~
q Planar passivated chips
q UL applied
Applications
q Switching and control of
three phase AC circuits
q Softstart AC motor controller
q Solid state switches
q Light and temperature control
Advantages
q Easy to mount with two screws
q Space and weight savings
q Improved temperature and power
cycling
q High power density
Data according to IEC 60747 refer to a single thyristor unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions.