VUE 50
VRRM = 1200 V
IdAV = 50 A
trr = 40 ns
VRSM
VRRM
Type
V
V
10
8
1200
1200
VUE 50-12NO1
6
1/2
45
12
10
4/5
8
6
Symbol
IdAV
IFSM
I2t
TVJ
TVJM
Tstg
VISOL
Md
Weight
Symbol
IR
VF
VT0
rT
RthJS
IRM
trr
dS
dA
a
Test Conditions
TK = 85°C, module
TVJ = 45°C;
VR = 0
TVJ = TVJM
VR = 0
TVJ = 45°C
VR = 0
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
50/60 Hz, RMS
IISOL £ 1 mA
Mounting torque
typ.
t = 1 min
t=1s
(M5)
(10-32UNF)
Test Conditions
VR = VRRM
VR = 0.8 VRRM
TVJ = 25°C
TVJ = 125°C
IF = 30 A;
TVJ = 25°C
For power-loss calculations only
per diode,
per module,
120° rect.
120° rect.
IF = 30 A, -diF/dt = 240 A/ms
VR = 540 V, L £ 0.05 mH, TVJ = 100°C
IF = 1 A; -di/dt = 100 A/ms; VR = 30 V, TVJ = 25°C
Creeping distance on surface
Creepage distance in air
Max. allowable acceleration
Maximum Ratings
50
A
200
A
210
A
185
A
195
A
200
A2s
180
A2s
170
A2s
160
A2s
-40...+150
°C
150
°C
-40...+125
°C
3000
V~
3600
V~
2 - 2.5
18-22
35
Nm
lb.in.
g
Characteristic Values
typ. max
0.75 mA
4
7 mA
2.55 V
1.65 V
18.2 mW
1.5 K/W
0.25 K/W
16
18 A
40
60 ns
12.7 mm
9.4 mm
50 m/s2
Features
q Package with DCB ceramic base plate
q Isolation voltage 3600 V~
q Planar passivated chips
q Leads suitable for PC board soldering
q Creeping and creepage-distance
fulfils UL 508/CSA 22.2NO14 and
VDE 0160 requirements
q Epoxy meet UL94V-O
q UL registered E72873
Applications
q Supplies for DC power equipment
q Input rectifiers for PWM inverter
q Output filter for PWM inverter
Advantages
q Reduced EMI/RFI
q Easy to mount with two screws
q Space and weight savings
q Improved temperature and power
cycling
Dimensions in mm (1 mm = 0.0394")
Data according to IEC 60747 and refer to a single diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions.
© 2000 IXYS All rights reserved
Use output terminals in parallel connections