English
Language : 

MLO36 Datasheet, PDF (1/3 Pages) IXYS Corporation – AC Controller Modules
AC Controller Modules
MLO 36
MMO 36
IRMS = 39 A
VRRM = 1200-1600 V
VRSM
VDSM
V
VRRM
VDRM
V
1200 1200
1600 1600
Type
MLO 36-12io1 MMO 36-12io1
MLO 36-16io1 MMO 36-16io1
MLO
G1 K1
K2
MMO
G1 K1
K2 G2
MMO 36
G1
K2
K1
G2
Symbol
IRMS
ITRMS
I
TAVM
ITSM
I2t
(di/dt)cr
(dv/dt)
cr
PGM
PGAVM
VRGM
TVJ
TVJM
Tstg
VISOL
Md
Weight
Test Conditions
TK = 85°C, 50 - 400 Hz (for single controller)
TVJ = TVJM
T
K
=
85°C;
(180°
sine)
TVJ = 45°C;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
T =T
VJ
VJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = TVJM
repetitive, IT = 150 A
f
=50
Hz,
t
P
=200
ms
VD = 2/3 VDRM
I = 0.3 A
non repetitive, I = I
G
T TAVM
diG/dt = 0.3 A/ms
T =T ;
V = 2/3 V
VJ
VJM
DR
DRM
RGK = ¥; method 1 (linear voltage rise)
TVJ = TVJM
IT = ITAVM
tp = 30 ms
tp = 300 ms
50/60 Hz, RMS
IISOL £ 1 mA
Mounting torque
typ.
t = 1 min
t=1s
(M3)
(UNF 4-32)
Maximum Ratings
39
A
28
A
18
A
360
A
390
A
320
A
350
A
645
A2s
630
A2s
510
A2s
510
A2s
100 A/ms
500 A/ms
1000 V/ms
10
5
0.5
10
-40...+125
125
-40...+125
3000
3600
0.7 ± 0.1
6 ± 0.9
15
W
W
W
V
°C
°C
°C
V~
V~
Nm
lb.in.
g
K1 = Cathode 1, G1 = Gate 1
K2 = Cathode 2, G2 = Gate 2
(MLO 36 has no G2 lead)
Features
q Thyristor controller for AC (circuit
W1C acc. to IEC) for mains frequency
q Direct copper bonded Al O -ceramic
23
base plate
q Isolation voltage 3600 V~
q Planar passivated chips
q UL registered, E 72873
q Long wire leads suitable for PC board
soldering
Applications
q Switching and control of single and
three phase AC
q Softstart AC motor controller
q Solid state switches
q Light and temperature control
Advantages
q Easy to mount with two screws
q Space and weight savings
q Improved temperature and power
cycling
q High power density
Data according to IEC 60747 and to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions.
© 2000 IXYS All rights reserved
1-3