English
Language : 

MCC19 Datasheet, PDF (1/4 Pages) IXYS Corporation – Thyristor Modules
Thyristor Modules
MCC 19
ITRMS = 2x 40 A
ITAVM = 2x 25 A
VRRM = 800-1600 V
VRSM
VDSM
V
900
1300
1500
1700
VRRM
VDRM
V
800
1200
1400
1600
Type
Version 1 B
MCC 19-08io1 B
MCC 19-12io1 B
MCC 19-14io1 B
MCC 19-16io1 B
Version 8 B
MCC 19-08io8 B
MCC 19-12io8 B
MCC 19-14io8 B
MCC 19-16io8 B
TO-240 AA
1
3
2
67
4
5
3 67 1 542
Symbol
ITRMS
ITAVM
ITSM
òi2dt
(di/dt)cr
(dv/dt)cr
PGM
PGAV
VRGM
TVJ
T
VJM
Tstg
V
ISOL
Md
Weight
Test Conditions
Maximum Ratings
TVJ = TVJM
TC = 58°C; 180° sine
TC = 85°C; 180° sine
TVJ = 45°C;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
T =T
VJ
VJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C
V =0
R
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = TVJM
repetitive, IT = 45 A
f =50 Hz, tP =200 ms
VD = 2/3 VDRM
IG = 0.45 A
non repetitive, IT = ITAVM
diG/dt = 0.45 A/ms
TVJ = TVJM;
VDR = 2/3 VDRM
RGK = ¥; method 1 (linear voltage rise)
TVJ = TVJM
IT = ITAVM
tP = 30 ms
tP = 300 ms
40
A
25
A
18
A
400
A
420
A
350
A
370
A
800
A2s
730
A2s
600
A2s
570
A2s
150 A/ms
500 A/ms
1000 V/ms
10
W
5
W
0.5
W
10
V
-40...+125
°C
125
°C
-40...+125
°C
50/60 Hz, RMS
t = 1 min
IISOL £ 1 mA
t=1s
Mounting torque (M5)
Terminal connection torque (M5)
3000
V~
3600
V~
2.5-4.0/22-35 Nm/lb.in.
2.5-4.0/22-35 Nm/lb.in.
Typical including screws
90
g
Version 1 B
Version 8 B
3
61
52
Features
q International standard package,
JEDEC TO-240 AA
q Direct copper bonded Al O -ceramic
23
base plate
q Planar passivated chips
q Isolation voltage 3600 V~
q UL registered, E 72873
q Gate-cathode twin pins for version 1B
Applications
q DC motor control
q Softstart AC motor controller
q Light, heat and temperature control
Advantages
q Space and weight savings
q Simple mounting with two screws
q Improved temperature and power
cycling
q Reduced protection circuits
Data according to IEC 60747 and refer to a single thyristor unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
1-4