English
Language : 

IXGK120N60A3 Datasheet, PDF (1/6 Pages) IXYS Corporation – GenX3 A3-Class IGBTS
GenX3TM A3-Class
IGBTS
Ultra-Low Vsat PT IGBTs for
up to 5kHz Switching
IXGK120N60A3
IXGX120N60A3
Symbol
VCES
VCGR
VGES
VGEM
IC25
IC110
ILRMS
ICM
SSOA
(RBSOA)
PC
TJ
TJM
Tstg
TL
TSOLD
Md
FC
Weight
Test Conditions
Maximum Ratings
TJ = 25°C to 150°C
TJ = 25°C to 150°C, RGE = 1MΩ
Continuous
600
V
600
V
±20
V
Transient
±30
V
TC = 25°C
TC = 110°C
Terminal Current Limit
TC = 25°C, 1ms
VGE= 15V, TVJ = 125°C, RG = 1.5Ω
Clamped Inductive Load
200
A
120
A
75
A
600
A
ICM = 200
A
@ < 600
V
TC = 25°C
780
W
-55 ... +150
°C
150
°C
-55 ... +150
°C
Maximum Lead Temperature for Soldering
300
°C
1.6 mm (0.062 in.) from Case for 10
260
°C
Mounting Torque ( IXGK )
Mounting Force ( IXGX )
1.13/10
20..120/4.5..27
Nm/lb.in.
N/lb.
TO-264
PLUS247
10
g
6
g
Symbol
Test Conditions
(TJ = 25°C, Unless Otherwise Specified)
VGE(th)
IC = 500μA, VCE = VGE
ICES
VCE = VCES, VGE = 0V
TJ = 125°C
IGES
VCE = 0V, VGE = ±20V
VCE(sat)
IC = 100A, VGE = 15V, Note 1
Characteristic Values
Min. Typ. Max.
3.0
5.0 V
50 μA
1.25 mA
±400 nA
1.20 1.35 V
VCES =
IC110 =
VCE(sat) ≤
600V
120A
1.35V
TO-264 (IXGK)
G
C
EE
PLUS 247TM (IXGX)
(TAB)
G
C
E
(TAB)
G = Gate
C = Collector
E = Emitter
TAB = Collector
Features
z Optimized for Low Conduction Losses
z Square RBSOA
z High Current Handling Capability
z International Standard Packages
Advantages
z High Power Density
z Low Gate Drive Requirement
Applications
z Power Inverters
z UPS
z Motor Drives
z SMPS
z PFC Circuits
z Battery Chargers
z Welding Machines
z Lamp Ballasts
z Inrush Current Protection Circuits
© 2009 IXYS CORPORATION, All Rights Reserved