English
Language : 

HVL900-16IO1 Datasheet, PDF (1/3 Pages) IXYS Corporation – AC Controller with Isolated Water Flow
AC Controller
with Isolated Water Flow
Preliminary data
VRSM
VDSM
V
1300
1500
1700
1900
VRRM
VDRM
V
1200
1400
1600
1800
Type
HVL 900 - 12io1
HVL 900 - 14io1
HVL 900 - 16io1
HVL 900 - 18io1
HVL 900
IRMS = 900 A
VRRM = 1200-1800 V
1
7
6
5
4
2/3
Symbol
IRMS
I ,I
TSM FSM
I2t
(di/dt)cr
(dv/dt)cr
PGM
PGAV
V
RGM
TVJ
TVJM
Tstg
VISOL
Weight
Test Conditions
TWater = 17°C; watervolume = 4 l/min
T
VJ
=
45°C;
VR = 0
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
T =T
VJ
VJM
VR = 0
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
TVJ = TVJM
V =0
R
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
TVJ = TVJM
repetitive, IT = 960 A
f
=50
Hz,
t
P
=
200
ms
VD = 2/3 VDRM
IG = 1 A,
diG/dt = 1 A/ms
TVJ = TVJM; VDR = 2/3 VDRM
RGK = ¥; method 1 (linear voltage rise)
TVJ = TVJM
IT = ITAVM
tP = 30 ms
tP = 500 ms
50/60 Hz, RMS t = 1 min
IISOL £ 1 mA
t=1s
Typical including screws
Maximum Ratings
900
A
9200
10100
8000
8800
423 000
423 000
320 000
321 000
100
A
A
A
A
A2s
A2s
A2s
A2s
A/ms
Features
q Isolation between water and electrical
connections with Direct copper
bonded Al O -ceramic
23
q Planar passivated chips
q Isolation voltage 3600 V~
q Keyed gate/cathode twin pins
Applications
q Large resistance welding equipment
q Large electroplating equipment
1000 V/ms
120
W
60
W
20
W
10
V
-40...+140
°C
140
°C
-40...+125
°C
3000
V~
3600
V~
1300
g
Data according to IEC 60747 refer to a single thyristor unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
1-3