English
Language : 

DSEK60-12A Datasheet, PDF (1/2 Pages) IXYS Corporation – Common Cathode Fast Recovery Epitaxial Diode (FRED)
Common Cathode
Fast Recovery
Epitaxial Diode (FRED)
DSEK 60
IFAVM = 2x 26 A
VRRM = 1200 V
trr = 40 ns
VRSM
V
1200
VRRM
V
1200
Type
DSEK 60-12A
TO-247 AD
A
A
C
A
C
A
C (TAB)
A = Anode, C = Cathode, TAB = Cathode
Symbol
IFRMS
IFAVM ÿÿx
IFRM
IFSM
I2t
TVJ
TVJM
Tstg
Ptot
Md
Weight
Symbol
IR
VF
VT0
rT
RthJC
RthCK
RthJA
trr
IRM
Test Conditions
TVJ = TVJM
TC = 85°C; rectangular, d = 0.5
tP < 10 ms; rep. rating, pulse width limited by TVJM
TVJ = 45°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TC = 25°C
Mounting torque
Maximum Ratings
50
A
26
A
375
A
200
A
210
A
185
A
195
A
200
A2s
180
A2s
170
A2s
160
A2s
-40...+150
°C
150
°C
-40...+150
°C
125
W
0.8...1.2
Nm
6
g
Test Conditions
Characteristic Values
typ.
max.
TVJ = 25°C
TVJ = 25°C
TVJ = 125°C
VR = VRRM
VR = 0.8 • VRRM
VR = 0.8 • VRRM
IF = 30 A;
TVJ = 150°C
TVJ = 25°C
For power-loss calculations only
TVJ = TVJM
0.25
IF = 1 A; -di/dt = 100 A/ms; VR = 30 V; TVJ = 25°C 40
VR = 540 V; IF = 30 A; -diF/dt = 240 A/ms
16
L £ 0.05 mH; TVJ = 100°C
750
250
7
2.2
2.55
1.65
18.2
0.9
70
60
18
mA
mA
mA
V
V
V
mW
K/W
K/W
K/W
ns
A
Features
q International standard package
JEDEC TO-247 AD
q Planar passivated chips
q Very short recovery time
q Extremely low switching losses
q Low I -values
RM
q Soft recovery behavior
q Epoxy meets UL 94V-0
Applications
q Rectifiers in switch mode power
supplies (SMPS)
q Uninterruptible power supplies (UPS)
q Ultrasonic cleaners and welders
Advantages
q High reliability circuit operation
q Low voltage peaks for reduced
protection circuits
q Low noise switching
q Low losses
q Operating at lower temperature or
space saving by reduced cooling
x IFAVM rating includes reverse blocking losses at TVJM, VR = 0.8 VRRM, duty cycle d = 0.5
Data according to IEC 60747 and refer to a single diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
1-2