English
Language : 

DSEI-12 Datasheet, PDF (1/2 Pages) IXYS Corporation – Fast Recovery Epitaxial Dioder (FRED)
Fast Recovery
Epitaxial Diode (FRED)
DSEI 12
IFAVM = 11 A
VRRM = 1200 V
trr = 50 ns
VRSM
V
1200
VRRM
V
1200
Type
DSEI 12-12A
TO-220 AC
A
C
C
A
C
A = Anode, C = Cathode
Symbol
IFRMS
IFAVM ÿÿx
IFRM
IFSM
I2t
TVJ
TVJM
Tstg
Ptot
Md
Weight
Symbol
IR
VF
VT0
rT
RthJC
RthCK
RthJA
trr
IRM
Test Conditions
TVJ = TVJM
TC = 100°C; rectangular, d = 0.5
tP < 10 ms; rep. rating, pulse width limited by TVJM
TVJ = 45°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TC = 25°C
Mounting torque
Maximum Ratings
25
A
11
A
150
A
75
A
80
A
65
A
70
A
28
A2s
27
A2s
21
A2s
20
A2s
-40...+150
°C
150
°C
-40...+150
°C
78
W
0.4...0.6
Nm
2
g
Test Conditions
TVJ = 25°C
TVJ = 25°C
TVJ = 125°C
VR = VRRM
VR = 0.8 • VRRM
VR = 0.8 • VRRM
IF = 12 A;
TVJ = 150°C
TVJ = 25°C
For power-loss calculations only
TVJ = TVJM
IF = 1 A; -di/dt = 50 A/ms; VR = 30 V; TVJ = 25°C
VR = 540 V; IF = 12 A; -diF/dt = 100 A/ms
L £ 0.05 mH; TVJ = 100°C
Characteristic Values
typ.
max.
250
mA
150
mA
4
mA
2.2
V
2.6
V
1.65
V
46.2
mW
1.6
K/W
0.5
K/W
60
K/W
50
70
ns
6.5
7.2
A
Features
q International standard package
JEDEC TO-220 AC
q Planar passivated chips
q Very short recovery time
q Extremely low switching losses
q Low I -values
RM
q Soft recovery behaviour
q Epoxy meets UL 94V-0
Applications
q Antiparallel diode for high frequency
switching devices
q Anti saturation diode
q Snubber diode
q Free wheeling diode in converters
and motor control circuits
q Rectifiers in switch mode power
supplies (SMPS)
q Inductive heating and melting
q Uninterruptible power supplies (UPS)
q Ultrasonic cleaners and welders
Advantages
q High reliability circuit operation
q Low voltage peaks for reduced
protection circuits
q Low noise switching
q Low losses
q Operating at lower temperature or
space saving by reduced cooling
x IFAVM rating includes reverse blocking losses at TVJM, VR = 0.8 VRRM, duty cycle d = 0.5
Data according to IEC 60747
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
1-2