English
Language : 

N153 Datasheet, PDF (2/4 Pages) Baumer IVO GmbH & Co. KG – Spindle Position Displays
Spindle Position Displays
Hollow shaft max. ø14 mm, with infrared interface
Format alignment by power tool, interface RS485
Part number
N 153. 1
3 A A 01
Hollow shaft
A Hollow shaft ø14 mm
Display
A Inclined
Voltage supply
3 24 VDC
E-connection
0 Connector output M8
1 Cable output M8
Interface
1 RS485
Accessories
Connectors and cables (page %S)
Z 178.A01 Adaptor cable between cable connector M8
and female M16, 1 m
Z 178.AW1 Cable connector M8, 4-pin, less cable with
integrated terminating resistor 120 Ω
Z 178.B01 Mating connector M8, 4-pin, less cable
Z 178.D05 Data and supply cable M8, Master to N 150
and N 155, 5 m
Z 178.S01 Cable connector M8, 4-pin, less cable
Z 178.V01 Coupling cable 1 m between M8 and M8
N 153
Description
multicon AccuDrive is an economical system for mobile,
motive format alignment. By AccuDrive positioning of shafts
to the desired format is quick, accurate and less fussy hand
crank operations. Saving setup times and avoiding editing
errors are consequently the most convincing arguments.
The electrically commutated professional power tool ASMIR
serves as mobile actuator that communicates with N 153
spindle position displays by infrared interface. Red and
green status LEDs provided at the position display indicate
the operator which shafts require alignment. A flashing LED
indicates the positioning order.
The power tool is a vital help in aligning the respective
shafts to the new format. Select the desired positioning di-
rection by aid of the two pushbuttons provided at the power
tool. Press and hold the start button to start the positioning
operation at slow speed with increasing acceleration. This
way, the operator is able to proceed the positioning opera-
tion in direct sight with an accuracy of ±1/100 mm.
Any shaft positions once effected can be filed under a
parameter profile in the control to be recalled any time. By
serial interface maximum 32 spindle position displays may
be networked to PC or PLC. Through solutions are real-
ized by memory controller N 242 as memory and operating
terminal where max. 100 format profiles can be entered and
saved by Teach-in.
2