N152 Datasheet, PDF (2/4 Pages) Baumer IVO GmbH & Co. KG – Spindle Position Displays
Spindle Position Displays
Hollow shaft max. ø14 mm, automatic format alignment
Display LCD two lines, interface RS485
Part number
N 152. 1
3
A 01
Hollow shaft
A Hollow shaft ø14 mm
Display
A Inclined
B Horizontal at front
Voltage supply
3 24 VDC
E-connection
1 Cable output M8, motor cable 0.5 m
2 Cable output M8, motor cable 1.5 m
Interface
1 RS485
Accessories
Connectors and cables
Z 178.A01 Adaptor cable between cable connector M8
and female M16, 1 m
Z 178.AW1 Cable connector M8, 4-pin, less cable with
integrated terminating resistor 120 Ω
Z 178.B01 Mating connector M8, 4-pin, less cable
Z 178.D05 Data and supply cable M8, Master to N 150
and N 155, 5 m
Z 178.S01 Cable connector M8, 4-pin, less cable
Z 178.V01 Coupling cable 1 m between M8 and M8
Z 178.Y01 Y-junction M8, 4-pin, with cable
N 152
Description
multiconDrive represents a simplified and very efficient,
reasonably priced system for automatic format alignment.
With multiconDrive the spindle position displays communi-
cate directly with EC motors. Every spindle position display
is connected to the corresponding motor by a separate
cable output providing the motor without delay with the
signals “clockwise”, “counterclockwise”, “rotation speed” for
switchover to high/low speed.
The spindle position display provides two keys for clock-
wise and counterclockwise direction used during the first
editing operation. The key makes the motor moving into the
requested direction. A soft touch results in a defined STEP.
Thus, new spindle positions can be edited under direct
visual check of the operator with an accuracy of ±1/100 mm.
Shaft position parameters once set can be filed as profile in
the control. The serial interface enables network of maxi-
mum 32 spindle position displays with PC or PLC. For com-
plete solutions N 242 memory controller as operating and
memory terminal is available. Up to 100 format profiles can
be stored by teach-in. The respective position parameters
can be retransmitted at any time as target to the respecitve
spindle position displays to release automatic format align-
ment cycles.
2