ISI30 Datasheet, PDF (2/4 Pages) Baumer IVO GmbH & Co. KG – Totalizers electronic
Totalizers electronic
Small impulse counters and position displays
Display LCD, 8-digits
ISI30, ISI31, ISI32, ISI33
Type table
ISI30 - Impulse counter
Without backlit
With backlit
Version
Brief description
Signal input INP A
Signal input INP B
Operating mode
ISI30.010AA01
ISI30.010AB01
NPN
Fast and slow
counting processes
Fast counting
NPN
7 kHz
Slow counting
NPN or floating contact
30 Hz
Adding or
subtracting
ISI30.012AA01
ISI30.012AB01
PNP
Fast and slow
counting processes
Fast counting
PNP
12 kHz
Slow counting
NPN or floating contact
30 Hz
Adding or
subtracting
ISI30.013AA01
ISI30.013AB01
AC/DC
Slow counting
processes
Slow counting
AC/DC
30 Hz
External reset
AC/DC
–
Adding
ISI31 - Up/down counter / Difference counter
Without backlit
With backlit
Version
Brief description
Signal input INP A, INP B
ISI31.010AA01
ISI31.010AB01
ISI31.011AA01
ISI31.011AB01
ISI31.013AA01
ISI31.013AB01
NPN
PNP
AC/DC
Fast counting processes with Fast counting processes with Slow difference
direction signal (Up/Down) or direction signal (Up/Down) or counting
difference counting
difference counting
NPN, 7 kHz
PNP, 12 kHz
AC/DC, 30 Hz
Operating mode
Counting with direction signal
INP A - Counting input
INP B - Direction signal
Difference counting
INP A - Adding
INP B - Subtracting
Counting with direction signal
INP A - Counting input
INP B - Direction signal
Difference counting
INP A - Adding
INP B - Subtracting
Difference counting
INP A - Adding
INP B - Subtracting
ISI32 - Up/down counter / ISI33 - Position display
Without backlit
With backlit
Version
Brief description
Signal input INP A
Signal input INP B
Operating mode
ISI32.013AA01
ISI32.013AB01
AC/DC
Slow, direction-
controlled counting
processes
Direction signal
AC/DC
30 Hz
Direction signal
AC/DC
30 Hz
Counting with
direction signal
ISI33.010AA01
ISI33.010AB01
NPN
For position display or lenght
measurement in conjunction
with an incremental encoder
Counting input 0°
NPN
3 kHz
Counting input 90° out of phase
NPN
3 kHz
INP A 90° INP B x1 or
INP A 90° INP B x2
ISI33.011AA01
ISI33.011AB01
PNP
For position display or lenght
measurement in conjunction
with an incremental encoder
Counting input 0°
PNP
6 kHz
Counting input 90° out of phase
PNP
6 kHz
INP A 90° INP B x1 or
INP A 90° INP B x2
2
www.baumerivo.com