English
Language : 

IRHYS67134CM_15 Datasheet, PDF (7/9 Pages) International Rectifier – Simple Drive Requirements
Pre-Irradiation
IRHYS67134CM, 2N7590T3
1000
100
OPERATION IN THIS AREA LIMITED
BY RDS(on)
10
100µs
1
1ms
Tc = 25°C
Tj = 150°C
Single Pulse
0.1
1
10
10ms
DC
100
1000
VDS , Drain-to-Source Voltage (V)
Fig 13. Maximum Safe Operating Area
120
ID
100
TOP
8.5A
12A
BOTTOM 19A
80
60
40
20
0
25
50
75
100
125
150
Starting TJ , Junction Temperature (°C)
Fig 14. Maximum Avalanche Energy
Vs. Drain Current
10
1
D = 0.50
0.20
0.10
0.1
0.05
0.02
0.01
0.01
0.001
1E-006
1E-005
SINGLE PULSE
( THERMAL RESPONSE )
P DM
t1
t2
Notes:
1. Duty Factor D = t1/t2
2. Peak Tj = P dm x Zthjc + Tc
0.0001
0.001
0.01
0.1
1
t1 , Rectangular Pulse Duration (sec)
Fig 15. Maximum Effective Transient Thermal Impedance, Junction-to-Case
www.irf.com
7