English
Language : 

IRAM630-1562F Datasheet, PDF (7/19 Pages) International Rectifier – Intelligent Power Module for Energy Efficient Compressor Applications
IRAM630-1562F
Dynamic Electrical Characteristics
VBIAS (VCC, VBS1,2,3)=15V, TJ=25ºC, unless otherwise specified. Driver only timing unless otherwise specified.
Symbol
Parameter
Min Typ Max Units Conditions
TON
TOFF
TFILIN
TFILEN
TEN
TFLT
TBLT-ITRIP
TITRIP
TPFCTRIP
DT
Input to Output propagation turn-
on delay time (see fig.11)
---
Input to Output propagation turn-
off delay time (see fig. 11)
---
Input filter time (HIN,LIN,PFC,EN) 200
Input filter time (FLT/EN)
100
EN low to six switch turn-off
propagation delay (see fig. 3)
---
ITRIP to Fault propagation delay
---
ITRIP Blanking Time
---
ITRIP to six switch turn-off
---
propagation delay (see fig. 2)
PFCTRIP to switch turn-off
---
propagation delay (see fig. 2)
Internal Dead Time injected by
driver
190
--- 1.15
--- 1.15
350
---
200
---
--- 1.15
800
---
500
---
---
1.5
---
1.5
290 420
µs
IC=5A, V+=400V
µs
ns VIN=0 or VIN=3.3V
ns VIN=0 or VIN=5V
µs VIN=0 or VIN=3.3V, VEN=0
ns VIN=0 or VIN=3.3V, VITRIP=3.3V
ns VIN=0 or VIN=3.3V, VITRIP=3.3V
µs IC=5A, V+=400V
µs IC=10A, V+=400V
ns VIN=0 or VIN=3.3V
MT
TFLT-CLR
Matching Propagation Delay Time
(On & Off) all channels
---
---
50
ns External dead time> 400ns
Post ITRIP to six switch turn-off
clear time (see fig. 2)
1.17
1.7
2.19
ms TC = 25°C
---
1.5
---
TC = 100°C
7 www.irf.com © 2013 International Rectifier
Submit Datasheet Feedback October 23, 2013