English
Language : 

ATW2800S_15 Datasheet, PDF (7/10 Pages) International Rectifier – HYBRID-HIGH RELIABILITY DC/DC CONVERTER
ATW28XXS Series
Table III. Electrical Performance Characteristics - continued
Test
Symbol
Conditions
-55°C ≤ Tc ≤ +125°C
Vin = 28 Vdc ±5%, CL = 0
unless otherwise specified
Group A
Subgroups
Device
Types
Recovery time step
TTLOAD 50% load to/from 100% load
4
All
transient load
changes 7, 8
5,6
No load to 50% load
4,5,6
50% load to no load
4,5,6
Output response to
transient step line
changes 5, 9
VOTLINE Input step 17 to 40 Vdc
4,5,6
All
Input step 40 to 17 Vdc
4,5,6
Recovery time
transient line
changes 5, 8, 9
TTLINE Input step 17 tp 40 Vdc
4,5,6
All
Input step 40 to 17 Vdc
4,5,6
Turn on overshoot
Turn on delay 10
VTonOS IOUT = 0 and 1333mA
TonD IOUT = 0 and 1333mA
4,5,6
All
4,5,6
All
Load fault recovery 5
Weight
TrLF
Flange
4,5,6
All
Limits
ATW2815S
Unit
Min Max
70
µs
100
1500
5.0
500
ms
mVpk
1500
800
ms
800
600
mVpk
10
ms
10
ms
75
g
Notes to Specifications
1 Parameter guaranteed by line and load regulation tests.
2 Bandwidth guaranteed by design. Tested for 20kHz to 2.0MHz.
3 For operation at 16 Vdc input, derate output power by 33%.
4 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance.
A capacitive load in excess of the maximum limit will not disturb loop stability but may interfere with the
operation of the load fault detection circuitry, appearing as a short circuit during turn-on.
5 Parameter shall be tested as part of design characterization and after design or process changes.
Thereafter, parameters shall be guaranteed to the limits specified in Table III.
6 An overload is that condition with a load in excess of the rated load but less than that necessary to
trigger the short circuit protection and is the condition of maximum power dissipation.
7 Load step transition time between 2.0µs and 10µs.
8 Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of VOUT at 50% load.
9 Input step transition time between 2.0µs and 10µs.
10 Turn-on delay time measurement is for either a step application of power at the input or the removal of
ground signal from the inhibit pin (pin 2) while power is applied to the input.
www.irf.com