English
Language : 

ATO2800T_15 Datasheet, PDF (7/7 Pages) International Rectifier – HYBRID-HIGH RELIABILITY DC/DC CONVERTER
ATO28XXT Series
Device Screening
Requirement MIL-STD-883 Method No Suffix
ES
HB
CH
Temperature Range
Element Evaluation
MIL-PRF-38534
-20°C to +85°C -55°C to +125°C
N/A
N/A
-55°C to +125°C -55°C to +125°C
N/A
Class H
Non-Destructive
Bond Pull
2023
N/A
N/A
N/A
N/A
Internal Visual
Temperature Cycle
Constant Acceleration
PIND
Burn-In
Final Electrical
( Group A )
PDA
Seal, Fine and Gross
Radiographic
External Visual
2017
1010
2001, Y1 Axis
2020
1015
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
2012
2009
N/A
N/A
N/A
N/A
25°C
N/A
Cond A
N/A
Yes
Cond B
500 Gs
N/A
48 hrs@hi temp
25°C
N/A
Cond A, C
N/A
Yes
Yes
Yes
Cond C
Cond C
3000 Gs
3000 Gs
N/A
N/A
160 hrs@125°C 160 hrs@125°C
-55°C, +25°C, -55°C, +25°C,
+125°C
+125°C
N/A
10%
Cond A, C
Cond A, C
N/A
N/A
Yes
Yes
Notes:
Best commercial practice
Sample tests at low and high temperatures
-55°C to +105°C for AHE, ATO, ATW
Part Numbering
ATO 28 15 T F /CH
Model
Input Voltage
Nominal
28 = 28V
Output Voltage
12 = 5V ±12V
15 = 5V ±15V
Screening Level
(Please refer to Screening Table)
No Suffix, ES, HB, CH
Package Style
F = Flange
Blank = Non-Flanged
Output
T = Triple
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 01/2007
www.irf.com
7