AMF28XXS Datasheet, PDF (7/7 Pages) International Rectifier – HYBRID - HIGH RELIABILITY RADIATION TOLERANT DC/DC CONVERTER
AMF28XXS Series
Device Screening
Requirement
MIL-STD-883 Method
Temperature Range
Element Evaluation
Non-Destructive Bond Pull
Internal Visual
Temperature Cycle
MIL-PRF-38534
2023
2017
1010
Constant Acceleration
PIND
2001, Y1 Axis
2020
Burn-In
1015
Final Electrical
( Group A )
PDA
Seal, Fine and Gross
Radiographic
External Visual
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
2012
2009
d No Suffix
-55°C to +125°C
Class H
N/A
Yes
Cond C
3000 Gs
Cond A
320 hrs @ 125°C
( 2 x 160hrs )
-55°C, +25°C,
+125°C
2%
Cond A, C
Yes
Yes
CH d
-55°C to +125°C
Class H
N/A
Yes
Cond C
3000 Gs
Cond A
320 hrs @ 125°C
( 2 x 160hrs )
-55°C, +25°C,
+125°C
2%
Cond A, C
Yes
Yes
EM
-55°C to +85°C
N/A
N/A
c
Cond C
3000 Gs
N/A
48 hrs @ 125°C
-55°C, +25°C,
+85°C
N/A
Cond A
N/A
c
Notes:
 Best commercial practice.
‚ Device with ‘/CH’ suffix is a DSCC class H compliant without radiation performance. No suffix is a radiation rated
device but not available as a DSCC qualified SMD per MIL-PRF-38534.
International Rectifier currently does not have a DSCC certified Radiation Hardness Assurance Program.
Standard Microcircuit Drawing Equivalence Table
Part Numbering
Standard Microcircuit
IR Standard
AMF 28 05 S /EM
Drawing Number
5962-04252
5962-04253
5962-04254
Part Number
AMF2805S
AMF2812S
AMF2815S
Model
Input Voltage
28 = 28V
Output Voltage
03R3 = 3.3V, 05 = 5V
07R5 = 7.5V, 12 = 12V
15 = 15V
Screening Level
(Please refer to Screening Table)
No suffix, CH, EM
Output
S = Single
D = Dual
www.irf.com
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 09/2008