English
Language : 

SBB501S Datasheet, PDF (6/11 Pages) International Rectifier – HIGH RELIABILITY CLASS K HYBRID RADIATION HARDENED, NON-ISOLATED
SBB SERIES
Single Output
Electrical Performance Characteristics ( continued )
Parameter
Group A
Subgroup
Conditions
-55°C ≤ TC ≤ +85°C
VIN = 5.0V DC ± 5%, CL = 0
unless otherwise specified
Recovery time,
step load changes (TTLD)
Output response to
step line changes (VTLN)
Recovery time,
step line changes (TTLN)
Turn-on Response
Overshoot (VOS)
Turn-on Delay (TDLY)
Capacitive Load (CL)
Line Rejection
Device Weight
4,5,6
4,5,6
4,5,6
4,5,6
1
1
Half Load to/from Full Load,
Notes 6,7
4.5V to/from 5.5V
IOUT = 100% rated load, Notes 1, 8
4.5V to/from 5.5V
IOUT = 100% rated load, Notes 1,7,8
No Load, Full Load,
Note 9
IOUT = 100% rated load
No effect on DC performance
Notes 1, 4
IOUT = 100% rated load
DC to 50KHz, Note 1
MTBF
MIL-HDBK-217F2, SF, 40°C
Min
-100
0.5
28
2.8 x106
Limits
Nom
Unit
Max
200
µs
100
200
100
10
10000
mV pk
µs
mV
ms
µF
dB
60
g
Hr
Electrical Performance Characteristics - Notes
1. Parameter is tested as part of design characterization or after design changes. Thereafter, parameter shall be
guaranteed to the limits specified.
2. Parameter verified during line and load regulation tests.
3. Guaranteed for a D.C. to 20MHz bandwidth. Tested using a 20KHz to 10MHz bandwidth.
4. Capacitive load may be any value from 0 to the maximum limit without compromising dc performance.
A capacitive load in excess of the maximum limit may cause erratic behavior during turn-on.
5. Overload power dissipation is defined as the device power dissipation with the load set such that VOUT = 90% of
nominal.
6. Load step transition time ≤ 1.0 µs/A for 3.3V & 2.5V models and ≤ 0.1 µs/A for 1.0V, 1.2V, 1.5V & 1.8V models.
7. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its
steady state value.
8. Line step transition time ≤ 10 µs.
9. Turn-on delay time from either a step application of input power or a logic low to a logic high transition on the
Enable pin (pin 10) to the point where VOUT = 90% of nominal.
Radiation Performance Characteristics
Test
Conditions
Min Typ
Unit
MIL-PRF-883, Method 1019
Total Ionizing Dose ( Gamma ) Operating bias applied during exposure, 100
Krads (Si)
2 / 3 Rated Load, VIN = 5.0V
Single Event Effects
SEU, SEL, SEGR, SEB
Heavy ions (LET)
Operating bias applied during exposure, 82
Full Rated Load, VIN = 5.5V
Test lab: Cyclotron Institute,
Texas A & M University
MeVycm2/mg
Notes: International Rectifier currently does not have a DLA Land and Maritime (formerly DSCC) certified
Radiation Hardness Assurance Program.
6