AUIRS212(7,71,8,81)S
Static Electrical Characteristics
Unless otherwise noted, these specifications apply for an operating junction temperature range of -40°C ≤ Tj ≤
125°C with bias conditions of V BIAS (VCC, VBS) = 15 V. The VIL, VIH and IIN parameters are referenced to COM. The
VO and IO parameters are referenced to VS.
Symbol
VIH
VIL
VCSTH+
Definition
Min Typ Max Units
Logic “1” input voltage
Logic “0” input voltage
Logic “0” input voltage
Logic “1” input voltage
(AUIRS2127/AUIRS21271)
(AUIRS2128/AUIRS21281)
2.5
—
—
(AUIRS2127/AUIRS21271)
(AUIRS2128/AUIRS21281)
—
—
0.8
V
CS input positive going (AUIRS2127/AUIRS2128) 180 250 320 mV
threshold
(AUIRS21271/AUIRS21281) 1.5 1.8 2.1
Test Conditions
VCC = 10 V to 20 V
VOH High level output voltage, VBIAS - VO
VOL Low level output voltage, VO
ILK Offset supply leakage current
IQBS Quiescent VBS supply current
IQCC Quiescent VCC supply current
IIN+ Logic “1” input bias current
IIN- Logic “0” input bias current
ICS+ “High” CS bias current
ICS- “High” CS bias current
— 0.05 0.2 V
— 0.02 0.1
— — 50
— 300 925
— 60 130
— 7.0 15 µA
— — 5.0
— — 5.0
— — 5.0
IO = 2 mA
VB = VS = 600 V
VIN = 0 V or 5 V
VIN = 5 V
VIN = 0 V
VCS = 3 V
VCS = 0 V
VBSUV+
VBS supply undervoltage (AUIRS2127/AUIRS2128) 8.8 10.3 11.8
positive going threshold (AUIRS21271/AUIRS21281) 6.3 7.2 8.2
V
VBSUV-
VBS supply undervoltage (AUIRS2127/AUIRS2128) 7.5 9.0 10.6
negative going threshold (AUIRS21271/AUIRS21281) 6.0 6.8 7.7
IO+
Output high short circuit pulsed current(†)
IO-
Output low short circuit pulsed current(†)
200 290
420 600
—
—
mA
VO = 0 V, VIN = 5 V
PW ≤ 10 µs
VO = 15 V, VIN = 0 V
PW ≤ 10 µs
Ron, FLT FAULT – low on resistance
(†) Guaranteed by design
— 125 — Ω
Dynamic Electrical Characteristic
Unless otherwise noted, these specifications apply for an operating junction temperature range of -40°C ≤ Tj ≤
125°C with bias conditions of V BIAS (VCC, VBS) = 15 V, CL = 1000 pF.
Symbol
Definition
Min Typ Max Units Test Conditions
ton
Turn-on propagation delay
toff
Turn-off propagation delay
tr
Turn-on rise time
tf
Turn-off fall time
tbl
Start-up blanking time
tcs
CS shutdown propagation delay
tflt
CS to FAULT pull-up propagation delay
— 200 275
— 175 275
— 80 130
— 40 65 ns
475 750 985
— 65 360
— 270 510
VS = 0 V
VS = 600 V
Note: Please refer to figures in Parameter Temperature Trends section
www.irf.com
© 2012 International Rectifier