Static Electrical Characteristics
Unless otherwise noted, these specifications apply for an operating junction temperature range of -40°C ≤ Tj ≤
125°C with bias conditions of VBIAS (VCC, VBS, VDD ) = 15 V, VSS = COM. The VIL, VTH and IIN parameters are
referenced to VSS and are applicable to all three logic input leads: HIN, LIN and SD. The VO, and IO parameters are
referenced to COM and are applicable to the respective output leads: HO or LO.
Symbol
Definition
Min Typ Max Units Test Conditions
VIH
VIL
VOH
VOL
ILK
IQBS
IQCC
IQDD
IIN+
IIN-
VBSUV+
VBSUV-
VCCUV+
VCCUV-
IO+
Logic “1” input voltage
Logic “0” input voltage
High level output voltage, VBIAS - VO
Low level output voltage, VO
Offset supply leakage current
Quiescent VBS supply current
Quiescent VCC supply current
Quiescent VDD supply current
Logic “1” input bias current
Logic “0” input bias current
VBS supply undervoltage positive going threshold
VBS supply undervoltage negative going threshold
VCC supply undervoltage positive going threshold
VCC supply undervoltage negative going threshold
Output high short circuit pulsed current (†)
IO-
Output low short circuit pulsed current(†)
(†) Guaranteed by design
9.5 — —
— — 6.0 V
— — 1.4
— — 0.15
— — 50
— 70 130
— 125 230 µA
— 5 30
— 20 40
— — 5.0
7.5 8.6 9.7
7.0 8.2 9.4 V
7.4 8.5 9.6
7.0 8.2 9.4
2.0 2.5 —
A
2.0 2.5 —
IO = 0 A
IO = 20 mA
VB = VS = 500
V/600 V
VIN = 0 V or VDD
VIN = VDD
VIN = 0 V
VO = 0 V,
VIN = VDD
PW ≤ 10 us
VO = 15 V,
VIN = 0 V
PW ≤ 10 us
Dynamic Electrical Characteristics
Unless otherwise noted, these specifications apply for an operating junction temperature range of -40°C ≤ Tj ≤
125°C with bias conditions of VBIAS (VCC, VBS, VDD ) = 15 V, CL = 1000 pF, and VSS = COM. The dynamic electrical
characteristics are measured using the test circuit shown in Fig. 3.
Symbol
ton
toff
tsd
tr
tf
MT
Definition
Turn-on propagation delay
Turn-off propagation delay
Shutdown propagation delay
Turn-on rise time
Turn-off fall time
Delay matching, HS & LS turn on/off
Min Typ Max Units Test Conditions
— 140 230
— 120 210
— 125 220
— 25 40 ns
VS = 0 V
VS = 500 V/600 V
— 15 30
— — 35
Note: Please refer to figures in Parameter Temperature Trends section
www.irf.com
© 2008 International Rectifier
6