English
Language : 

ATR28XXS Datasheet, PDF (6/12 Pages) International Rectifier – HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
ATR28XXS Series
Specifications
ABSOLUTE MAXIMUM RATINGS
Input Voltage
-0.5V to 50V
Soldering Temperature
300°C for 10 seconds
Case Temperature
Operating -55°C to +125°C
Storage -65°C to +135°C
Table III. Electrical performance Characteristics
Test
Output voltage
Output current 1
Output ripple voltage 2
Line regulation 3
Load regulation 3
Input current
Input ripple current 2
Efficiency
Isolation
Capacitive load 4, 5
Power dissipation
load fault
Switching frequency
Sync frequency range
Output response to step
transient load changes 7
Recovery time step
transient load changes 7, 8
Output response to
transient step line
changes 5, 9
Symbol
VOUT
IOUT
VRIP
VRLINE
VRLOAD
IIN
IRIP
EFF
ISO
CL
PD
FS
FSYNC
VOTLOAD
TTLOAD
Conditions
-55°C ≤ TC ≤ +125°C
VIN = 28VDC ±5%, CL = 0
Unless otherwise specified
IOUT = 0
VIN = 16, 28, and 40 VDC
VIN = 16, 28, and 40 VDC
B.W. = 20Hz to 2 MHz
VIN = 16, 28, and 40 VDC
IOUT = 0, 1250, and 2500mA
VIN = 16,28, and 40 VDC
IOUT = 0, 1250, and 2500mA
IOUT = 0, inhibit (pin 2)
Tied to input return (pin 10)
IOUT = 0, inhibit (pin 2) = open
IOUT =2500mA
B.W. = 20Hz to 2 MHz
IOUT=2500mA
Input to output or any pin
To case (except pin 8) at
500 VDC, TC =+25°C
No effect on dc performance
TC =+25°C
Overload, TC = +25°C 6
Short Circuit
IOUT = 2500mA
IOUT = 2500mA
1250mA to/from 2500mA
200mA to/from 1250mA
1250mA to/from 2500mA
200mA to/from 1250mA
VOTLINE
Input step 16V to/from
40VDC, IOUT = 2500mA
Group A
Subgroups
1
2,3
1,2,3
1,2,3
1
2,3
1
2,3
1,2,3
1
2,3
1,2,3
1
2,3
1
4
1
1,2,3
4,5,6
4,5,6
4,5,6
4,5,6
4
5,6
4
5,6
4,5,6
Device
Types
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
ATR2812S
Limits
Units
Min
11.88
11.70
80
75
100
Max
12.12
12.30
2500
60
±30
±60
±60
±120
18
50
75
50
V
mA
mVp-p
mV
mV
mA
mAp-p
%
MΩ
500
500
-800
-1000
500
12
9
600
700
+800
+1000
100
200
100
200
±1200
µF
W
KHz
KHz
mV pk
µs
mV pk
For Notes to Specifications, refer to page 7
6
www.irf.com