English
Language : 

AUIPS6031_15 Datasheet, PDF (5/17 Pages) International Rectifier – INTELLIGENT POWER HIGH SIDE SWITCH
AUIPS6031(S)(R)
Protection Characteristics
Tj=-40°C..150°C, Vcc=6..28V (unless otherwise specified), typical values are given for Vcc=14V and Tj=25°C
Symbol Parameter
Min. Typ. Max. Units Test Conditions
Ilim
Tsd+
Tsd-
Vsc
UV+
UV-
VOL Off
Internal current limit
10 16
23
Over temperature high threshold
150(1) 165 
Over temperature low threshold

158

Short-circuit detection voltage(2)
2
3
4
Under voltage protection Vcc going up

5
6.2
Under voltage protection Vcc going down  4.5 5.8
Open load detection threshold
2
3
4
A
Vout=0V, Tj=25°C
°C See fig. 2
V
I OL On
Open load detection threshold
0.15 0.4 0.65
0.15 0.4 0.55
A
Tj=-40..25°C
Tj=25..150°C
(1) Guaranteed by design
(2) Reference to Vcc
True Table
Operating Conditions IN OUT
DG
Normal
H
H
H
Normal
L
L
H
Open Load
H
H
L
Open Load (3)
L
H
L
Short circuit to Gnd
H
L
L
Short circuit to Gnd
L
L
H
Short circuit to Vcc
H
H
L (4)
Short circuit to Vcc (5)
L
H
L
Over-temperature
H
L
L
Over-temperature
L
L
H
(3) With a pull-up resistor connected between the output and Vcc.
(4) Vds lower than 10mV.
(5) Without a pull-up resistor connected between the output and Vcc.
Lead Assignments
www.irf.com
5