ATR28XXS_07 Datasheet, PDF (5/12 Pages) International Rectifier – HYBRID-HIGH RELIABILITY DC/DC CONVERTER
ATR28XXS Series
Table II. Electrical performance Characteristics - continued
Recovery time transient step
line changes 5, 8, 9
Turn on overshoot
Turn on delay 10
Load fault recovery 5, 10
Symbol
TTLINE
VTonOS
TonD
TrLF
Conditions
-55°C ≤ TC ≤ +125°C
VIN = 28VDC ±5%, CL = 0
Unless otherwise specified
Input step 16V to/from
40VDC, IOUT = 6000mA
IOUT =0 and 6000mA
IOUT =0 and 6000mA
Group A
Subgroups
4,5,6
4,5,6
4,5,6
4,5,6
Device
Types
01
01
01
01
ATR2805S
Limits
Units
Min Max
10
ms
500 mV pk
25
ms
25
ms
Notes to Specifications
1 Parameter guaranteed by line and load regulation tests.
2 Bandwidth guaranteed by design. Tested for 20KHz to 2.0MHz.
3 Output voltage measured at load with remote sense leads connected across load.
4 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of
the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing
as a short circuit during turn on.
5 Parameter shall be tested as part of design characterization and after design or process changes. There after parameters shall be
guaranteed to the limits specified in table II.
6 An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit
protection and is the condition of maximum power dissipation.
7 Load step transition time between 2.0µs and 10µs.
8 Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of VOUT at 50% load.
9 Input step transition time between 2.0µs and 10µs.
10 Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 2) while power is applied to the input.